Power supply · regulated, 960 W, 3-phase

Primary switchmode power supply, PFC, 3-phase, screw terminalInput: Wide range input AC 340 - 576 V; DC 480 - 820 VOutput: 24 V / 48 V - adjustable

DescriptionPart-No.TypePU Screw terminal Output voltage/currentDC 24 V; 40 A722806WRA 960-241 DC 48 V; 20 A 722810 WRA 960-48 1 Input WRA 960-24 WRA 960-48 VoltageAC 400–500 V Operation voltage range AC 340–575 V; DC 480–820 V Line frequency47–63Hz Rated current V
in = 400 V; AC: 2,4 A / V
in = 480 V; AC: 1,6 A Inrush current30 A Input industrial fuse T6, 3 A / internal per phase Power Factor Correction P.F.C.0,7 Output

Dimensions PIN assignment Derating Parallel mode

Rated voltage outputDC 24 VDC 48 V Rated current output 40 A 20 A Voltage trim range22.5–28.5 V47–56 V Accuracy 1 % Line regulation±1 % Load regulation Single ±1 %, Parallel ±5 % Transient recovery time– Temperature coefficient ±0.02 % / °C Ripple & Noise80mV Hold up time min. 20 ms Status indication DC ON (LED green)>17.6–19.4 V<37–43 V Status indication DC LOW (LED red) >17.6–19.4 V <37–43 V Parallel modemax. 2 units at 90% load current, terminal P, G for current share Efficiency 92 % Rated over load protectionRated over load protection: 110 % –130 % Over voltage protection 125–137 % 125–142 % Short circuit characteristicsCurrent limit General Switching frequencymin. 100 kHz Isolation voltage input/output 3kVeff Isolation resistance at DC 500 V100M Operation temperature range -25°C – 71°C (Derating) Derating-3.5% / °C starting at 61°C Storage temperature range -25°C–85°C M.T.B.F.210000h Relative humidity 20–95% RH Dimensions276.0×125.0×118.0mm Cooling Air convection Housing materialmetal Field installation rail TS 35 (EN 50022) Installation postitionvertical IP rating IP20 Protection class– Weight (per unit) 3,2kg/ 7.053 lbs TerminationScrew terminal: 0.2–5.0 mm
2 Approvals UL: UL 508 listedcUL: UL 60950-1 anerkanntTÜV: EN 60950-1; CE: EN 61000-6-3 / EN 55022 Class BEN 6100-3-2, EN 6100-3-3, EN 61000-6-2, EN 55024 Monitoring DC ON Control (Rdy) Normally open – Switching voltageDC 60 V– Switching current max. 300 mA – Switcing capacity– Isolation voltage DC 500 V –

18

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
pdf-page pdf di En 2008-11-47-22