You may also be interested in
Camera, Pyrometer, Portable pyrometer, Infrared temperature sensor, Fixed pyrometer
Text version of the page
Metallic surfaces, ceramics, graphite Glass surfaces
Comfort class High speed Small, low-priced
Measuring material
Properties
Instrument
Benefits
Temperature ranges
(between... and...)
Spectral range
Field of view
(Minimum spot size
in mm)
Exposure time t90
1)
Output
IMPAC
pyrometers
IP 140
IPE 140
Fully digital, very fast
pyrometer for measurments
of low temperatures
on metals.
View finder or laser
targeting light, very
small spot sizes,
focusable optics.
Display, setting keys,
max.value storage.
Analog output, digital
interface.
50...1300°C
5...1200°C
2...2.8 ìm
3...5 ìm
3 focusable optics
min 400 : 1 (min 0.25)
1.5 ms 2)
adjustable up to 10 s
0/4 - 20 mA,
RS232 or RS485
(switchable)
IP 140-LO
Fully digital, very fast
pyrometer for measuring
of low temperatures
on metals.
Fibre, two optics
available, laser targeting
light, very small
spot sizes LC-display,
instrument settings,
analog output, digital
interface, maximum
value storage.
100...750°C
2...2.6 ìm
optical head I
min 35 : 1 (min 3.4)
optical head II
min 80 : 1 (min 1.1)
1.5 ms 2)
adjustable up to 10 s
0/4 - 20 mA,
RS232 or RS485
( switchable)
IPE 140/39
Special versions of
IPE 140:
For measurement of
objects in flame
heated furnaces,
sees through clean
combustion flames
and hot gases.
20...1450°C
3.9 ìm
3 focusable optics
min 200 : 1 (min 0.7)
1.5 ms 2)
adjustable up to 10 s
0/4 - 20 mA,
RS232 or RS485
(switchable)
ISR 12-LO
IGAR 12-LO
Fully digital, very fast
pyrometer in 2-colour
design (switchable to
mono mode), with
long fibre optic cable
lengths up to 30 m,
display and laser targeting
light, very
small spot sizes,
analog output and
digital interface, maximum
value storage.
600...3300°C
300...2200°C
0.8...1.1 ìm
1.28...1.7 ìm
optical head I
min 100 : 1 (min 1.2)
optical head II (focusable)
min 200 : 1 (min 0.45)
2 ms 2)
0/4 - 20 mA,
RS232 or RS485
(switchable)
Measuring material
Properties
Instrument
Benefits
Temperature ranges
(between... and...)
Spectral range
Field of view
(Minimum spot size
in mm)
Exposure time t90
1)
Output
IMPAC
pyrometers
ISR 50-LO
Fast digital, fibre
optic ratio pyrometer
(switchable to 1-color
design). Analog
output, digital
interface, maximum
value storage,
laser targeting light.
Two optical
heads available. Very
small spot sizes.
700...3000°C
channel 1: 0.9 ìm
channel 2: 1.05 ìm
optical head I
min 100 : 1 (min 1.2)
optical head II (focusable)
min 200 : 1 (min 0.45)
< 10 ms
adjustable up to 10 s
0/4 - 20 mA,
RS232 or RS485
(switchable)
Note: Coloured data in the table are only valid for the respective type of pyrometer, the black data for all types of the same column.
ISQ 5
ISQ 5-LO
Digital, fast pyrometers
in 2-colour design
(switchable to mono
mode) with analog
output and digital
interface, max. value
storage, adjustable
temp. range, laser
targeting light or view
finder or integrated
TV camera. Two optical
heads available
600...3000°C
700...2500°C
channel 1: 0.9 ìm
channel 2: 1.05 ìm
min 200 : 1 (min 1.5)
opt. head I: min 100 : 1
(min 1.2); II (focusable):
min 200 : 1 (min 0.45)
< 10 ms
adjustable up to 10 s
0/4 - 20 mA,
RS232 or RS485
PID controller (option)
Metallic surfaces, ceramics, graphite
Ratio pyrometers
M 90-R1
M 90-R2
Portable ratio
pyrometer with
precision optics.
Data logger, peak,
valley and variable
averaging functions
of a measurement
series
700...2000°C
900...3000°C
channel 1: 0.92 ìm
channel 2: 0.98 ìm
60 : 1 (min 8.4)
180 : 1 (min 2.8)
500 ms
analog output
1 mV/°C or 0 - 1 V
RS232
IN 300/5
Glass surface
measurement version
of IN 300,
2 wire design,
spectral range
5.14 ìm
300...1300°C
5.14 ìm
2 fixed optics
40 : 1 (min 2.5)
100 ms
4 - 20 mA
IGA 740
IGA 740-LO
Ultra fast pyrometers
with targeting light
(option: view finder),
very small spot sizes
variable or
fixed optics.
160...2500°C
200...2500°C
1.58...1.8; 1.58...2.2 ìm
or 2...2.2 ìm
focusable optics
min 200 : 1 (min 0.7)
2 stand. optical heads
90:1 (min 1.6); 10 special
6 ìs
0/4 - 20 mA
0 - 10 V
M 770-S
Digital, fast ratio
pyrometer with analog
output and digital
interface.
Variable focusing
view finder,
temperature display.
300...2500°C
narrow bands
near infrared
3 fixed optics
60 : 1 (min 0.8)
90 : 1 (min 1.8)
180 : 1 (min 0.8)
7,5 ms
adjustable up to 1 s
4 - 20 mA
RS485
|
|