SOFTSTARTERS15PAGE15-2 PAGE15-3 PAGE15-3 6Ato 1200A starter ratingsStandard and severe-duty typesInternal by-pass contactor up to245A ratingTorque ramp startingTotal motor protection incorporatedClock calendarDigital control and adjustmentRS232 and RS485serial ports forremote supervision and controlModbus®-RTU and proprietaryASCII communication protocols.ADXM...BP ADX...BP ADX...B •Rated starter current Ie 6 to 45A ratings•Rated motor power •For standard duty, starting current 3.5•Ie •Rated starter current Ie 22 to 231A ratings •Rated motor power, 9.2 to 110kW at380/415VAC•Reduced voltage soft starter with torque controland built-in by-pass contactor•Maximum starting current limitation •PC remote control supervision •Modbus •For severe duty, starting current 5•Ie •Rated starter current Ie 17 to 245A ratings •Rated motor power, 7.5 to 132kW at380/415VAC•Reduced voltage soft starter with torque controland built-in by-pass contactor•Maximum starting current limitation •PC remote control supervision •Modbus 2.2 to 22kW at 400VAC•Integrated by-pass relay •Total protection against over-temperature •Acceleration and deceleration time adjustable on front•LED indicator of starter status •Fixing on 35mm DIN rail.OGIC -L ® -RTU and property ASCIIcommunication protocols•LCD backlit screen. ® -RTU and property ASCIIcommunication protocols•LCD backlit screen. LANET P Soft startersSEC.PAGEADXM...BPtypewith integrated by-pass relay . . . . . . . . . . . . . . . . . . . . . . . . . . 15-2 ADX...BP type for standard duty with integrated by-pass contactor . . . . . . . . . 15-3 ADX...B type for severe dutywith integrated by-pass contactor . . . . . . . . . . . . . 15-3 ADX... type for severe dutypredisposed for external by-pass contactor . . . . . . 15-3 Remote keypad and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-4 Remote control software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-5No jumpers ordip switchesPAGE15-3ADX •For severe duty, starting current 5•Ie •Rated starter current Ie, 310A to1200A ratings •Rated motor power, 160kW to 630kW at380/415VAC•Reduced voltage soft starter with torque control,predisposed for external by-pass contactor•Maximum starting current limitation •PC remote control supervision •Modbus® -RTU and property ASCII communication protocols•LCD backlit screen. Alarm and event log TorquecontrolLCD screen anduser-friendlykeypad for control parameters and programming in multilanguage Standardsupplied RS232and RS485serial ports Wide input voltage range:208-500VAC50/60Hz Internal by-passcontactor up to 245A ratingProgrammableinputs and outputs |
|