PROTECTION RELAYS - LOVATO ELECTRIC - #9

/ 30


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
Pages:


See other catalogues for LOVATO ELECTRIC

Text version of the page
Protection relays For single-phase Systems Bisctric Voltage monitoring relay Ordercode Rated voltage to control Ue Qty per pkg Wt [V] 50/60Hz n° [kg] Single-phase system. Minimum and maximum AC voltage. Delayed trip. PMV55 A240 208-240VAC 1 0.125 PMV55 A440 380-440VAC 1 0.125 General characteristics - Voltage monitoring relay, self powered, for minimum and maximum voltage - 4 configurable rated voltage (Ue): • PMV55 A240: 208-220-230-240VAC • PMV55 A440: 380-400-415-440VAC - Excellent tripping accuracy - TRMS measurements (True Root Mean Square) - 1 relay output with 1 changeover contact (SPDT) - Modular DIN 43880 housing, 2-module - IEC protection degree: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals. ADJUSTMENTS "V max" Maximum voltage tripping threshold 105-115% Ue "V min" Minimum voltage tripping threshold 80-95% Ue "Delay" for each Tripping time 0.1-20s "Reset delay" Resetting time 0.1-20s Certifications and compliance Certifications obtained: GOST; UL Listed, for USA and Canada (File E93601), as Auxiliary Devices. Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14. Operational diagram See page 17-16. PMV55... Current monitoring relay Order code Rated Auxiliary Qty Wt current supply per Ie voltage pkg [A] [V] n° [kg] General characteristics - Current monitoring relay for AC/DC maximum current control, AC/DC multivoltage auxiliary power supply - Direct connection up to 16A max, or by current transformer (CT) - Excellent tripping accuracy - TRMS current measurements (True Root Mean Square) - Resetting and inhibition input - 1 relay output with 1 changeover contact (SPDT) - Modular DIN 43880 housing, 2-module - IEC protection degree: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals. ADJUSTMENTS "Imax" Maximum current tripping threshold 5-100% Ie "Hysteresis" Maximum hysteresis thresold 1-50% "Trip delay" Tripping time 0.1-30s "Inhibition time" Tripping delay for external input or at power up 1-60s "Aut. reset delay" Automatic resetting time 0.1-30s "Mode" • Rated current 5A or 16A, • Relay output normally energised or de-energised • Tripping memory (Latch) On or Off. Certifications and compliance Certifications obtained: GOST; UL Listed, for USA and Canada (File E93601), as Auxiliary Devices - Modular ampere monitoring relays. Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14. Single-phase system. AC/DC maximum current control. Auxiliary AC/DC power supply. Automatic or manual reset. PMA20 240 5 or 16A 24-240V 1 0.121 AC/DC PMA20 240 Operational diagram See page 17-17. Dimensions page 17-14 Wiring diagrams pages 17-16 and 17 Technical characteristics pages 17-24 and 26 17-8

pageCatalog pdf di En 2012-05-22-30