You may also be interested in
Motor circuit breaker, Interface, Power supply, Circuit breaker, Current transformer
Text version of the page
linecard32607.qxp table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.60pt "Arial", sans-serif; } .font1 { font:6.00pt "Tahoma", sans-serif; } .font2 { font:9.00pt "Tahoma", sans-serif; } .font3 { font:13.00pt "Tahoma", sans-serif; } Level control relays Start-up priority change relay Modular version Order code Auxiliary Type of Qty Wt supply output per voltage contacts pkg [V] n° [kg] General characteristics The relays are designed to balance the operating time, and hence the wear of pumps, compressors, generators, when two units - primary and stand-by - are installed. Operational characteristics - Operating limit: 0.85-1.1 Ue - Connection: permanent - Green LED indicator for power on - Red LED indicators for output relay state - Modular DIN 43880 housing, 1 module - IEC degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals. Certifications and compliance Certifications obtained: UL Listed, for USA and Canada (File E93601), as Auxiliary Devices - Automatic starting control. Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n° 14. 2 outputs. AC/DC supply voltage. LVMP05 24/48VDC 2 N/O (SPST) 1 0.090 24-240VAC LVMP05 Order code Auxiliary Type of Qty Wt supply output per voltage contacts pkg [V] 50/60Hz n° [kg] 2 outputs. AC supply voltage. LVMP10 A024 24VAC 2 N/O (SPST) 1 0.250 LVMP10 A127 110-127VAC 2 N/O (SPST) 1 0.250 LVMP10 A240 220-240VAC 2 N/O (SPST) 1 0.250 LVMP10 A415 380-415VAC 2 N/O (SPST) 1 0.250 General characteristics The relays are designed to balance the operating time, and hence the wear of pumps, compressors, generators, when two units - primary and stand-by - are installed. Operational characteristics - Operating limit: 0.85-1.1 Ue - Connection: permanent - Green LED indicator for power on - Red LED indicators for output relay state - Modular DIN 43880 housing, 3 modules - IEC degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals. Certifications and compliance Certifications obtained: UL Listed, for USA and Canada (File E93601), as Auxiliary Devices - Automatic starting control. Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n° 14. LVMP10... g-in version Order code Auxiliary Type of Qty Wt supply output per voltage contacts pkg [V] 50/60Hz n° [kg] 2 outputs. AC supply voltage. 31 CSP2E 24 24VAC 2 N/O (SPST) 1 0.150 31 CSP2E110 110VAC 2 N/O (SPST) 1 0.150 31 CSP2E 220 220VAC 2 N/O (SPST) 1 0.150 31 CSP2E 230 230/240VAC 2 N/O (SPST) 1 0.150 General characteristics The relays are designed to balance the operating time, and hence the wear of pumps, compressors, generators, when two units - primary and stand-by - are installed. Operational characteristics - Operating limit: 0.85-1.1 Us - Connection: permanent - Voltage applied across input contacts: 15VDC not isolated with respect to supply. - Current consumption, input contacts: about 1mA. - Plug-in housing for use with 31 S11 socket; suitable for screw fixing or fixing on 35mm DIN rail. - IEC degree of protection: IP30. Reference standards Compliant with standards: IEC/EN 60255-5. 31 CSP2E... Accessories page 18-7 Dimensions page 18-8 Wiring diagrams page 18-11 Technical characteristics page 18-13 18-6
|
|