| Operational characteristics - Ambient conditions: • Operating temperature: -25...+60°C • Storage temperature: -40...+70°C - Any mounting position is allowed - Degree of protection: • IP20 for contact elements On front: • Per IEC/EN: IP65 • Per UL: type 1, 2, 3R, 4, 4X, 12, 12K. Materials An aluminium and zinc alloy (zama) is used for the metal parts whereas plastic parts are made of polyamide and polycarbonate. The sealing boot is made of NBR rubber. Mechanical endurance Mechanical life: 1,000,000 cycles General characteristics of auxiliary contacts Self-cleaning with dual effect, scraping and oscillating Rated insulation voltage: 690V Rated thermal current Ith: 10A. Designation acording to IEC 60947-5-1 - A300 Q300. Operational power in AC15: |