|
catalogue search
|
You may also be interested in
Interface, Digital multimeter, Relay, Beacon, Energy meter
Text version of the page
table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.80pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Arial", sans-serif; } .font5 { font:7.00pt "Courier New", monospace; } .font6 { font:8.00pt "Lucida Sans Unicode", sans-serif; } .font7 { font:10.00pt "Lucida Sans Unicode", sans-serif; } Contactors Four-pole contactors BG09 T4 A BF09 A T4A-BF18 T4 A m ■m * BF26 T4 A-BF38 T4 A BF65 40 - BF80 40 B1154-B180 4 B250 4-B400 4 Résistive load control Order code AC coil IEC operating current Ith (AC1) <40°C <55°C <70°C Maximum IEC power at <40°C (AC1) 230V 400V 415V 440V 500V 690V 1000V UL/CSA General (purpose) use [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] [A] 11 BG09 T4 AO© 20 18 15 (<60°C) 8 14 14 15 16 22 — 20 11 BGF09 T4 AO 20 18 15 (<60°C) 8 14 14 15 16 22 — 20 11 BGP09 T4 AO 20 18 15 (<60°C) 8 14© 14© 15© 16© — — 20 BF09 T4 AO© 25 20 18 9.5 16 17 18 21 27 — 25 BF12 T4 AO 28 23 20 10 18 19 20 23 32 — 28 BF18 T4 AO© 32 26 23 12 21 22 23 26 36 — 32 BF26 T4 AO© 45 36 32 17 30 31 33 37 51 — 45 BF38 T4 AO© 56 (60©) 45 (48©) 40 (42©) 21 36 38 40 45 62 — 55 11 BF50 40O© 90 80 65 34 59 64 65 74 98 — 90 11 BF65 40O© 110 90 70 41 72 78 80 95 112 — 110 11 BF80 40O 125 100 80 47 82 90 90 108 128 — 125 11 B115 4 00©© 160 150 110 57 98 107 115 129 173 250 160 11 B145 4 00©© 250 235 190 91 150 162 180 196 270 390 250 11 B180 4 00©© 275 250 200 95 160 177 200 213 298 430 275 11 B250 4 00©© 350 300 250 124 214 234 255 282 380 560 350 11 B310 4 00©© 450 370 300 158 270 293 325 350 488 700 450 11 B400 4 00©© 550 430 360 200 345 377 400 452 598 870 550 11 B500 4 00©© 700 550 500 252 438 478 500 575 755 1100 11 B630 4 00©© 800 640 540 288 500 545 580 655 860 1250 11 B630 1000 4 00©© 1000 850 700 350 600 630 725 750 1000 1600 1000 11 B1250 4 24©© 1250 1050 880 480 830 900 905 1100 1450 2000 No UL/CSA 11 B1600 4 24©© 1600 1360 1120 550 950 1000 1160 1200 1650 2500 No UL/CSA O Complete order code with coil voltage digit or voltage digit followed by 60 if 60Hz. © Standard voltages are as follows: © - AC 50/60Hz 024 / 048 / 110 / 230 / 400V - AC 60Hz 024 60 / 048 60 / 120 60 / 220 60 / 230 60 / 460 60 / 575 60 (V). Example: 11 BG09 T4 A230 for mini-contactor BG09, four poles, with 230VAC 50/60Hz coil. 11 BG09 T4 A460 60 for mini-contactor BG09, four poles, with 460VAC 60Hz coil. © © The coil of the contactor can be powered indifferently in AC or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: © - AC/DC 24 / 48 / 60 / 110-125 (indicate 110) / 220-240 (indicate 220) / 380-415 (indicate 380) / 440-480V (indicate 440). Example: 11 B145 4 00 110 for contactor B145, four poles, without auxiliary contacts and with © 110-125VAC/DC coil. © The 24VAC/DC voltage is not possible for B500-B630 1000 contactors. Other voltages available on request. © If predisposed for mechanical latch (G495), the order code becomes 11 B...4SL 00 ©. If already fitted with mechanical latch (G495), the order code becomes 11 B...4L.00 © 0. 0 Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. Standard voltages are: -- AC 50/60Hz 48 / 110-125 indicate 110 / 220-240 indicate 220 / 380-415V indicate 380 - DC 48 / 110-125 indicate 110 / 220-240V indicate 220. Example: 11 B145 4L 00 110 C220 for contactor B145, four poles, without auxiliary contacts, with 110-125VAC/DC coil and mechanical latch powered at 220-240VDC. G495 mechanical latch cannot be mounted. Complete the order code with the digit of the coil voltage. For 110-125VAC 50/60 Hz indicate 110 or 220-240VDC 50/60 Hz indicate 220. Example: 11 B1250 4 24 110 for contactor B1250, four poles, with 2NO+4NC auxiliary contacts and 110-125VAC/DC 50/60Hz coil. Maximum voltage is limited at 300V for UL. For certified type up to 600V. Consult Customer Service for information; see contact details on inside front cover. Whenever the BF26 T4 or BF38 T4 types need to be mechanically interlocked with either the BFX50 00 or BFX50 01, the add-on fourth pole of one of the contactors needs to be removed from the right side and fitted on the left side. For use at this other current value, a 16mm2 cable, headed with a fork terminal, must be used. Definite-purpose (DP) contactors are available. Consult Customer Service for information; see contact details on inside front cover. Add-on blocks / Accessories pages 2-16 to 27_ Dimensions pages 2-32 to 38 Wiring diagrams page 2-45 Spare parts pages 2-28 to 31
|