CONTACTORS - LOVATO ELECTRIC - #9

/ 72


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
P. 49
P. 50


See other catalogues for LOVATO ELECTRIC
You may also be interested in

Interface, Digital multimeter, Relay, Beacon, Energy meter


Text version of the page
table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.80pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Arial", sans-serif; } .font5 { font:7.00pt "Courier New", monospace; } .font6 { font:8.00pt "Lucida Sans Unicode", sans-serif; } .font7 { font:10.00pt "Lucida Sans Unicode", sans-serif; } Contactors Four-pole contactors BG09 T4 A BF09 A T4A-BF18 T4 A m ■m * BF26 T4 A-BF38 T4 A BF65 40 - BF80 40 B1154-B180 4 B250 4-B400 4 Résistive load control Order code AC coil IEC operating current Ith (AC1) <40°C <55°C <70°C Maximum IEC power at <40°C (AC1) 230V 400V 415V 440V 500V 690V 1000V UL/CSA General (purpose) use [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] [A] 11 BG09 T4 AO© 20 18 15 (<60°C) 8 14 14 15 16 22 — 20 11 BGF09 T4 AO 20 18 15 (<60°C) 8 14 14 15 16 22 — 20 11 BGP09 T4 AO 20 18 15 (<60°C) 8 14© 14© 15© 16© — — 20 BF09 T4 AO© 25 20 18 9.5 16 17 18 21 27 — 25 BF12 T4 AO 28 23 20 10 18 19 20 23 32 — 28 BF18 T4 AO© 32 26 23 12 21 22 23 26 36 — 32 BF26 T4 AO© 45 36 32 17 30 31 33 37 51 — 45 BF38 T4 AO© 56 (60©) 45 (48©) 40 (42©) 21 36 38 40 45 62 — 55 11 BF50 40O© 90 80 65 34 59 64 65 74 98 — 90 11 BF65 40O© 110 90 70 41 72 78 80 95 112 — 110 11 BF80 40O 125 100 80 47 82 90 90 108 128 — 125 11 B115 4 00©© 160 150 110 57 98 107 115 129 173 250 160 11 B145 4 00©© 250 235 190 91 150 162 180 196 270 390 250 11 B180 4 00©© 275 250 200 95 160 177 200 213 298 430 275 11 B250 4 00©© 350 300 250 124 214 234 255 282 380 560 350 11 B310 4 00©© 450 370 300 158 270 293 325 350 488 700 450 11 B400 4 00©© 550 430 360 200 345 377 400 452 598 870 550 11 B500 4 00©© 700 550 500 252 438 478 500 575 755 1100 11 B630 4 00©© 800 640 540 288 500 545 580 655 860 1250 11 B630 1000 4 00©© 1000 850 700 350 600 630 725 750 1000 1600 1000 11 B1250 4 24©© 1250 1050 880 480 830 900 905 1100 1450 2000 No UL/CSA 11 B1600 4 24©© 1600 1360 1120 550 950 1000 1160 1200 1650 2500 No UL/CSA O Complete order code with coil voltage digit or voltage digit followed by 60 if 60Hz. © Standard voltages are as follows: © - AC 50/60Hz 024 / 048 / 110 / 230 / 400V - AC 60Hz 024 60 / 048 60 / 120 60 / 220 60 / 230 60 / 460 60 / 575 60 (V). Example: 11 BG09 T4 A230 for mini-contactor BG09, four poles, with 230VAC 50/60Hz coil. 11 BG09 T4 A460 60 for mini-contactor BG09, four poles, with 460VAC 60Hz coil. © © The coil of the contactor can be powered indifferently in AC or DC. Complete the order code only with the digit of the coil voltage. Standard voltages are: © - AC/DC 24 / 48 / 60 / 110-125 (indicate 110) / 220-240 (indicate 220) / 380-415 (indicate 380) / 440-480V (indicate 440). Example: 11 B145 4 00 110 for contactor B145, four poles, without auxiliary contacts and with © 110-125VAC/DC coil. © The 24VAC/DC voltage is not possible for B500-B630 1000 contactors. Other voltages available on request. © If predisposed for mechanical latch (G495), the order code becomes 11 B...4SL 00 ©. If already fitted with mechanical latch (G495), the order code becomes 11 B...4L.00 © 0. 0 Indicate rated voltage of the mechanical latch, preceded by the letter C if in DC. Standard voltages are: -- AC 50/60Hz 48 / 110-125 indicate 110 / 220-240 indicate 220 / 380-415V indicate 380 - DC 48 / 110-125 indicate 110 / 220-240V indicate 220. Example: 11 B145 4L 00 110 C220 for contactor B145, four poles, without auxiliary contacts, with 110-125VAC/DC coil and mechanical latch powered at 220-240VDC. G495 mechanical latch cannot be mounted. Complete the order code with the digit of the coil voltage. For 110-125VAC 50/60 Hz indicate 110 or 220-240VDC 50/60 Hz indicate 220. Example: 11 B1250 4 24 110 for contactor B1250, four poles, with 2NO+4NC auxiliary contacts and 110-125VAC/DC 50/60Hz coil. Maximum voltage is limited at 300V for UL. For certified type up to 600V. Consult Customer Service for information; see contact details on inside front cover. Whenever the BF26 T4 or BF38 T4 types need to be mechanically interlocked with either the BFX50 00 or BFX50 01, the add-on fourth pole of one of the contactors needs to be removed from the right side and fitted on the left side. For use at this other current value, a 16mm2 cable, headed with a fork terminal, must be used. Definite-purpose (DP) contactors are available. Consult Customer Service for information; see contact details on inside front cover. Add-on blocks / Accessories pages 2-16 to 27_ Dimensions pages 2-32 to 38 Wiring diagrams page 2-45 Spare parts pages 2-28 to 31

pageCatalog pdf di En 2012-05-22-30