A
UTOMATICPOWERFACTORCONTROLLERS
17
P
AGE
17-2
D
ESCRIPTION
DCRKDCRJDCRJ12F
DCRK SERIES Front plate >
Digital programming5 or 7 step configuration in 96x96mm housing
8 or 12 step configuration in 144x144mmhousingCapacitor overload protection
Internal panel temperature sensor
TTL/RS232 programming interface
Automatic set-up function Configurable alarms.
3-digit display ●●● >
Microprocessor supervision and controlAccurate current evaluation with RMS readingsAutomatic rational adjustment
Versionswith 5, 7, 8 or 12 steps;one with static outputsUse in co-generation systems
Communication serial interfaces
ASCII and Modbus
4-digit display supplement ●● 4 operation keys ●●● 1 function key ●● >
OGIC 7 LED indicators for main functions and measures ● 14 LED indicators for main functions and measures ●● >
-L Control - Functions Automatic recognition of current flow ●●● 4-quadrant operation ●●● Independent voltage input ●● Three-phase
voltage control ●● Medium-voltage usage ●● >
LANET Phase-Neutral connection in 3-phase systems ●● >
-RTUcommunication protocols.
P Programmable input as functional ●● or remote temperature sensor
Keypad lock ●●● TTL/RS232 communication interface ● >
Automatic power factor controllers
S
EC .P
AGE RS232 communication interface ●● >
DCRK series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-2
Isolated RS485 communication interface ●● >
DCRJ series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-3
P
AGE
17-3
Automatic set-up function (adjustable) ●● Easy current transformer setting function ●●● DCRJ SERIES >
Digital programming
8 or 12 step configurationin 144x144mmhousingDual displays
Independent voltage measure input
Capacitor overload protection
Internal-external panel temperature sensor
RS232 programming and supervision interface
RS485 supervision interface
Voltage and current harmonics measures
Event log
Automatic set-up function (adjustable)
Configurable alarms
Suitable for medium voltage systems.
Set-up and automatic panel test software ●● Remote supervision software ●● Real time clock with back-up battery ●● Current and voltage waveform captures, ●● related to harmonic events
Events logging such as: alarms, power ON, ●● power OFF, set-up changes, etc. Measures Instantaneous displacement power factor (cos ϕ ) ●●● Instantaneous and average weekly power factor ●●● Voltage and current ●●● Reactive power to reach set-point value ●●● Total reactive power ●●● Capacitor overload ●●● Electric panel temperature ●●● Maximum voltage and current value ●●● Maximum capacitor overload value ●●● Maximum panel temperature value ●●● Maximum capacitor temperature value ●● Active and apparent power ●● Current and voltage
harmonic analysis ●● Current and voltage harmonic waveform ●● logged at overload eventsStep var value ●● Number of switching measures per step ●● >
P
AGE
17-3
Protection functions Voltage too high and too low ●●● DCRJF TYPE (STATIC OUTPUTS) Current too high and too low ●●● >
Digital programming
11 step + 1 alarm configuration in 144x144mmhousingDual displays
Independent voltage measure input
Capacitor overload protection
Internal-external panel temperature sensor
RS232 programming and supervision interface
Voltage and current harmonics measures
Event log
Configurable alarms.
Over compensation (
capacitors manufacturer disconnected ●●● and cos ϕ higher than set-point)Under compensation (capacitors connected ●●● and cos ϕ lower than set-point)Capacitor overload ●●● Capacitor overload on all 3 phases ●● Over temperature ●●● No-voltage release protection ●●●
Capacitor bank failure ●● Over maximum harmonic distortion level limit ●● Programmable alarm properties ●●● (enable, trip delay, relay energising, etc.) >