You may also be interested in
Turbine flow-meter, Digital indicator, Indicator, Flow-meter, Rotary piston meter
Text version of the page
All rights reserved, Design Right protected VFF4.docx
VFF4
Model: VFF4/SS/414 bar VFF Rotary Piston Positive Displacement Flowmeter
Body:
414bar (6000 psi) body provided in 316 stainless steel with ½” NPT female process connections in-line. Higher pressure
versions available with connections to suit e.g. AE MP 3/8”OD tube. Alternate materials are available such as titanium,
duplex, super duplex and 17-4PH steel.
Rotor:
The rotor is provided in either anti galling stainless steel (AG, Nitronic 60), Brass (B) or Carbon graphite (C), with a 316SS
encapsulated magnet depending on the application. Part code becomes VFF4/SS/414/AG etc.
Seal:
There is a single FPM O-ring seal between the top cap and body. Other elastomers are available e.g. Kalrez®, FEP covered
silicon and in higher pressure versions PTFE and Inconel.
Pick-up/Transmitter:
There is one reed switch installed in a SS housing which is O-sealed to the meter body providing a rating of IP68. The
optional Ex ia or Ex d display is mounted on the housing. Typical reed switch life is 30 years at continuous maximum
operating flow rate.
Pressure rating:
414, 690, 1035, 1380 and 2500 bar. Lower pressure ratings are all served by the 414bar version. (6000, 10000, 15000,
20000 and 36000 psi). Part code becomes VFF4/SS/690 etc.
Temperature rating:
-40°C to +150°C (subject to chemical compatibility, pressure rating and location of the display), higher temperature
sensor available.
Pulse output: The unit provides a reed switch output with 83 pulses per litre (315 pp USG).
Viscosity range:
0.8 to 2000 cSt or greater. The normal meter maximum flow rate applies for viscosities from 1.2 to 30 cSt. For higher
viscosities up to 2000 cSt a reduced maximum flow rate may apply.
Flow rate range:
- Normal flow rate range 0-240 l/hr (0-4000 ml/min, 63 USG/hr, 1510 USGPD). Minimum flow rate repeatably measured
relates to application viscosity and rotor type; for example less than 12 ml/min for 11 cSt. Consult Litre Meter for
rangeability at specific viscosities with specific rotor materials.
- 50% over-range capability available for some applications – Please consult Litre Meter.
Filtration: A 100 micron filter is advisable for 100% long life serviceability. If filtration is not possible, consult Litre Meter.
Accuracy:
A calibration certificate is provided based on a representative viscosity fluid for the application. The calibration
certificate confirms the flowmeter accuracy. Improved system accuracy can be provided typically to ±1% of actual
reading where the linearisation signal processing facility of the display instrument is employed.
Optional Display,
remote or head mounted:
Display of rate and total (as shown), battery, loop powered, 24 Vdc, 110 Vac, 240 Vac, optional flow alarms. GRP or Aluminium.
Exia display of rate and total (as shown), battery or loop-powered, optional flow alarms, ATEX. GRP or coated aluminium.
Exd display of rate and total, 24Vdc, 3 or 4 wire with Optional HART, MODBUS or Fieldbus comms. ATEX or UL. Coated aluminium or
stainless.
Documentation:
Operating & Maintenance
Manual
LM0333 with Quick Start Info on LM0548
Installation Drawing C6086 with Exia display, C5830 with Exd. Flanged versions: C6087 & C5826 respectively. If in doubt ask factory advice.
Conformity: These products conform to PED and EMC. Hazardous Area approved as standard.
Flowmeter Specification Sheet
Standard Rotor: minimum flow Rotor: minimum flow
minimum Carbon l/hr USGPD AG l/hr USGPD
Water 15.00 95.102 Water 30.00 190.204
3cSt 2.40 15.216 3cSt 4.20 26.629
10cSt 2.00 12.680 10cSt 3.50 22.190
50cSt 1.60 10.144 50cSt 2.80 17.752
250cSt 1.00 6.340 250cSt 1.75 11.095
Optional Rotor: minimum flow Rotor: minimum flow
at extra cost Carbon l/hr USGPD AG l/hr USGPD
£350 Water 10.00 63.401 Water 20.00 126.803
3cSt 1.20 7.608 3cSt 2.40 15.216
10cSt 1.00 6.340 10cSt 2.00 12.680
50cSt 0.80 5.072 50cSt 1.60 10.144
250cSt 0.50 3.170 250cSt 1.00 6.340
|
|