You may also be interested in
Totalizer, Rotary piston meter, Flow indicator, Digital indicator, Controller
Text version of the page
LMX+ Series
Inline Pelton Wheel flowmeter with integral flow straighteners, providing a pulse output.
Model Type Flow Rate Range Pressure Drop
LMXS.003 or LMX.003* 0.004 to 0.060 l/min 0.18 bar @ 0.03 l/min; 0.7 bar @ 0.06 l/min
LMXS.005 or LMX.005 0.006 to 0.100 l/min 0.18 bar @ 0.05 l/min; 0.7 bar @ 0.10 l/min
LMX.01 0.01 to 0.25 l/min 0.33 bar @ 0.125 l/min; 1.3 bar @ 0.25 l/min
LMX.05 0.02 to 1.3 l/min 0.18 bar @ 0.65 l/min; 0.74 bar @ 1.3 l/min
LMX.24 0.03 to 4.3 l/min 0.3 bar @ 2 l/min: 1.2 bar @ 4.3 l/min
LMX.45 0.04 to 6.3 l/min 0.23 bar @ 3 l/min: 1.3 bar @ 6.3 l/min
LMX.48 0.06 to 8 l/min 0.30 bar @ 4 l/min: 1.2 bar @ 8 l/min
LMX.90 0.08 to 15 l/min 0.25 bar @ 9 l/min: 0.7 bar @ 15 l/min
LMX.220 0.1 to 28 l/min 0.24 bar @ 10 l/min: 1.8 bar @ 28 l/min
LMX.12.5 1 to 65 l/min 0.2 bar @ 32l/min: 0.9 bar @ 65 l/min
*Lower flows on request
Common Features:
Pressure Rating
LMXS.003 & 005 30bar
LMX. 100bar
Temperature Rating 100° C
Viscosity Range Up to 10 cPs; ring factory if higher
Accuracy
±2% of actual reading for the top 90% of
range. ±0.5% FSD for the bottom 10% of
range. [003 and 005 linearisation
required]
Repeatability ±0.2% reading over top 90% of range
Pipe Size
LMXS.003 and 005
LMXS: 8mm OD tube for optional Swagelok fittings to ¼" NPT, ¼" BSP. Other options available on
request. LMX: ½”NPT and BSP normally in stock.
LMX. 1/2” BSP or NPT male (Specify at time of order)
End to end length/Weight 180mm. LMXS003 and 005 can be reduced in length to 80mm; less than 2kg
Body and Internals 316SS with Teflon PFA rotor and sapphire/sapphire bearings, sealed ferrites on rotor
Seal PTFE Gasket (LMXS003 and 005 use FPM O ring)
External materials of sensing electronics 316SS or 303SS and anodised aluminium
Output & Power
NPN open collector with 4-way M12 sensor connector [IEC-61076-2-101] – e.g. compatible with Brad
Harrison, Hirschmann, ERNI and Turck Banner. Supplied with 5m cable – bare ends. 8 to 28Vdc input.
Options:
Output PNP or TTL (identified by green or blue cap respectively). Also divide by 2, 4 or 10 function
Connections Plain OD pipe for butt welding (as on LMXS) or flanges available in alternate styles
Flow rate, temperature and pressure Alternate ratings available in different sizes and styles, consult factory for further details
Seals FEP covered Silicon, EPDM or Kalrez® for chemical protection
IS Hazardous Area Version ATEX
Available in alternate styles to EEx ia IIC T5 – consult factory for further details (limited to process
temperatures up to 70°C) Consult factory for input and output data. Housed in an IP65 epoxy coated
die-cast aluminium body-mounted enclosure with 5pin DIN socket.
SB or BB IS Electronics pickup
For use either when instrumentation is also included in the hazardous area or an M20 gland is required.
Body-mounted stainless steel or Naval Brass IP68 enclosure, one or two M20x1.5 gland entries.
Documentation:
Operating and Maintenance Manual LM0093 with General Information LM0092
Installation Drawing C5220
Conformity: These products conform to PED and EMC. ATEX option available.
Flowmeter Specification Sheet
|
|