You may also be interested in
Digital indicator, Turbine flow-meter, Indicator, Rotary piston meter, Flow-meter
Text version of the page
LMGN+ Series
Low cost, plastic bodied Pelton Wheel flowmeter with push-on hose connections, providing a pulse output.
Model Type Flow Rate Range Pressure Drop
LMGN.003* 0.004 to 0.060 l/min 0.18 bar @ 0.03 l/min; 0.7 bar @ 0.06 l/min
LMGN.005 0.006 to 0.100 l/min 0.18 bar @ 0.05 l/min; 0.7 bar @ 0.10 l/min
LMGN.01 0.01 to 0.25 l/min 0.33 bar @ 0.125 l/min; 1.3 bar @ 0.25 l/min
LMGN.05 0.02 to 1.3 l/min 0.18 bar @ 0.65 l/min; 0.74 bar @ 1.3 l/min
LMGN.24 0.03 to 4.3 l/min 0.3 bar @ 2 l/min: 1.6 bar @ 4.3 l/min
LMGN.45 0.04 to 6.3 l/min 0.16 bar @ 3 l/min: 0.71 bar @ 6.3 l/min
LMGN.90 0.08 to 15 l/min 0.33 bar @ 7.5 l/min: 1.33 bar @ 15 l/min
LMGN.220 0.1 to 28 l/min 0.19 bar @ 10 l/min: 1.5 bar @ 28 l/min
*Lower flows on request
Common Features:
Pressure Rating 2 bar 70°C; 5 bar 40°C
Temperature Rating 70° C
Viscosity Range Up to 10 cPs; ring factory if higher
Accuracy
±2% of actual reading for the top 90% of
range. ±0.5% FSD for the bottom 10% of
range. [003 and 005 linearisation
required]
Repeatability ±0.2% reading over top 90% of range
Pipe Size
LMGN except 220 Push on Hose Connections – hose id is 8mm
LMGN.220 Push on Hose Connections – hose id is 11mm
Weight Less than 1kg
Body and Internals 316SS with Teflon PFA rotor and sapphire/sapphire bearings
Ferrites Sealed
Seal FPM ‘O’ ring (subject to chemical compatibility).
Wetted parts of sensing electronics 316SS
External materials of sensing electronics 316SS or 303SS and anodised aluminium
Output & Power
NPN open collector with 4-way M12 sensor connector [IEC-61076-2-101] – e.g. compatible with Brad
Harrison, Hirschmann, ERNI and Turck Banner. Supplied with 5m cable – bare ends. 8 to 28Vdc input.
Options:
Output PNP or TTL (identified by green or blue cap respectively). Also divide by 2, 4 or 10 function
Connections Plain OD pipe for butt welding or flanges available in alternate sizes and styles
Flow rate, temperature and pressure Alternate ratings available in different sizes and styles, consult factory for further details
Seals FEP covered Silicon, EPDM or Kalrez® for chemical protection
IS Hazardous Area Version ATEX
Available with a threaded body to EEx ia IIC T5 – consult factory for further details (limited to process
temperatures up to 70°C) Consult factory for input and output data. Housed in an IP65 epoxy coated
die-cast aluminium body-mounted enclosure with 5pin DIN socket.
Documentation:
Operating and Maintenance Manual LM0093 with General Information LM0092
Installation Drawing C5220
Conformity: These products conform to PED and EMC. ATEX option available.
Flowmeter Specification Sheet
|
|