You may also be interested in
Flow indicator, Rotary piston meter, Indicator, Digital indicator, Controller
Text version of the page
F112.docx
F112 Display of Rate & Total
Model: F112 Flow rate/total and accumulated total display instrument, 15 point linearisation.
Display LCD/keys:
High Intensity reflective numeric and alphanumeric LCD: 40 x 90mm (1.6"x3.5"). Seven 17mm (0.67")
and eleven 8mm (0.32") digits. Three industrial micro-switch keys with UV-resistant silicone keypad.
HD Casing: Sturdy IP67 / NEMA 4X GRP casing. Polycarbonate window. Silicone seals.
Mounting: Direct mounting or Wall mounting. 130 x 120 x 75 mm (5.1"x4.72"x2.95") WxHxD.
Operating Temperature: -30°C to +80°C (-22°F up to 176°F) (IS -30°C to +70°C (-22°F up to 158°F))
Power supply: 8-28 V dc. (Or via 4-20mA output see AP options below)
Configuration: Configuration is done at SETUP-level. SETUP-level can be protected with a password.
Data protection: EEPROM backup of all settings (every minute). Data retention at least 10 years.
P Flowmeter - pulse
input:
Coil/sine wave (sensitivity selectable), reed switch, NPN/PNP or NAMUR. Minimum 0 Hz. - maximum
10 KHz. Flowmeter supply voltage: 3.2 VDC. For NAMUR and some other signal pick-ups, external
power to the flowmeter is required. (see PM option below). A: analogue input option
Time/Date: Clock function available for operator and remote communication.
OPERATOR FUNCTIONS:
TOTAL: 17mm character-size - 7 digits. Total is resettable; 11 digit accumulated total is not.
Measuring units: L, m3, GAL, USGAL, KG, lb, bbl, no unit. Maximum three decimal places.
K-factor: 7 positions 0.000010 - 9,999,999.
FLOWRATE: 8mm or 17mm character-size - 5 or 7 digits. Settings independent of TOTAL.
Measuring units: ml, l, m3, gallons, kg, ton, lb, bl, cf, rev (for RPM), ft³, scf, Nm³, Nl, igal, no
unit. Maximum three decimal places.
Time units: Seconds, minutes, hours, days.
KL-factor: 7 positions 0.000010 - 9,999,999.
Pulse 3 outputs available, choice of combination.
Selected Options
AA Analogue Output: Active 4-20mA output (requires option PD or PM).
AP Analogue Output: Non isolated passive 4-20mA – 10 bit resolution; scalable to flow rate.
AF Analogue Output: Isolated passive 4-20mA – 10 bit resolution; scalable to flow rate.
AU Analogue Output: Active 0-10V output (requires option PD or PM).
CB RS232 Communication:
RS232 (2-wire) Modbus protocol ASCII / RTU. All functionality and display
information is available for communication. CT: TTL Intrinsically Safe
CH: RS485 2-wire
CI: RS485 4-wire
HC GRP Casing: Panel cut-out: 115 x 98 mm (4.53” x 3.86”) – WxH
HA Aluminium casing: IP67 aluminium casing with one M20 and two PG9 cable entries. Dimensions: as HD
HV GRP Casing: HD mounted direct on VFF HL GRP Casing:
HD mounted direct on LM Pelton
wheel
OT Pulse Output:
Passive transistor output. Scalable in relation to total: i.e. pulse per X quantity- maximum
output frequency 64Hz. Pulse-width 7.8 or 2000 ms. OA: Active 24Vdc PNP
OR Pulse Output: Electromechanical relay output – isolated; max 230Vac NO, 0.5A per relay; must be PF or PM
PB or PC Supply: Lithium Battery, life time dependent upon settings. Average life time approx five years
PD Supply: 8-28 Vac/dc - sensor supply voltage 8 - 12 and 24Vdc - max. 50mA@24Vdc
PL Supply: 4-20mA loop powered from sensor
PM Supply:
2-24 Vac/dc or 115-240 Vac supply. The module contains an adjustable power supply to the
sensor of 8-24VDC; maximum supply 50mA @ 24Vdc.
SN Mounting Stem: 303 SS Mounting Stem (M20(m) x 1” NPT(f))
XI Hazardous area approval: EEx ia IIB T4 to CENELEC approval available
ZB LCD: Transflective LCD with green LED backlight for full sunlight and darkness – safe area only.
Documentation:
Operating & Maintenance Manual HF112PEN_v0204_04
Conformity: These products conform to LVD, EMC and optionally ATEX
Instrument Specification Sheet
|
|