Differential pressure transducer - Liquid Controls - #1

/ 2


catalogue search
Differential pressure transducer - Liquid Controls
P. 01
Differential pressure transducer - Liquid Controls
P. 02
Pages:
Differential pressure transducer - Liquid Controls


See other catalogues for Liquid Controls

Text version of the page

Specification Sheet

Differential Pressure (∆(∆(∆(∆(∆ P) Transducer

US Patent Number 20070044865

The differential pressure transducer monitors the differential pressure (pressuredrop) between a point immediately upstream and a point immediately downstream of the full flow fuel monitor, water coalescer, or other device typically applied inaviation fueling systems. The maximum differential pressure observedduring thefuel delivery is electronically input into the LectroCount
® LCR-II
® Electronic Register.The highest differential pressure reached during the delivery is printed on the delivery ticket to provide a record of the maximumpressure drop. Thecorresponding flow rate at which this maximum differential pressure is observed is printed immediately after the differential pressure reading. This information appears on the delivery ticket in the form:

DP 12.4 PSI @ 242.6 GPM

In the aviation industry, a differential pressure of more than 25 PSID across the full flow fuel monitor is considered unacceptable according to ATA Specification 103. A differential pressure more than 15 PSID across a water coalescer is considered unacceptable. The differential pressure transducer has a maximum differential pressure of 60.0 PSID. Interlocks on the LCR-II electronic register, if employed,shut down fuel delivery if the differential pressure reaches or exceeds theprogrammed differential pressure shutdown value.This system is designed for application on Jet Fuel delivery vehicles, hydrant carts,and stationary systems and is currently available for use with the Liquid Controls LectroCount
® LCR-II
® Electronic Register with SR214 operating software (version4.04 or higher) and compatible ticket software. Sample ticket

Technical Specifications

Environment al Rating Pressure Rating Differential measurement range ? 0-43.5 PSID (0 to 3 bar) for rated accuracy [60 PSID (4 bar) overpressure limit]Line pressure range ? 0 to 150 PSI (0 to 10.3 bar) IP67 (similar to NEMA 4X) Safety Designed to meet Class I, Division 2 Groups C and D requirements Materials of ConstructionBody Accuracy ±0.2% of full scale(±0.088 PSID from -4º to 104ºF, -20º to 40ºC) : Stainless steel (316L) Wetted Materials: Stainless steel (316L),Viton
® seals Power Applicable Product sClass 2: +10 to 28VDC, <4mA Jet Fuel T emperature Limit s Communication Protocol -40° to 176°F (-40° to 80°C) RS485
Viton ® is a registered trademark of DuPont Dow Elastomers LLC.

Website Edition

www.lcmeter.com

pageCatalog pdf di En 2012-05-22-30