Vertical Multistage Electric Pumps - Linn-Pumpen - #1

/ 6


catalogue search
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 01
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 02
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 03
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 04
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 05
Vertical Multistage Electric Pumps - Linn-Pumpen
P. 06
Pages:
Vertical Multistage Electric Pumps - Linn-Pumpen


See other catalogues for Linn-Pumpen

Text version of the page
Linn-Pumpen GmbH
Gewerbering 15 D-58579 Schalksmühle Telefon:+49 (0)2355-902929 Telefax:+49 (0)2355-902999
SSV
Mehrstufige vertikale Pumpen
Baureihen SV 2, SV 4, SV 8, SV 16
SSV
Vertical Multistage Electric Pumps
SV Series SV 2, SV 4, SV 8, SV 16
Einsatzgebiete
Gewerblicher und Industrieller Einsatz, Gebäudetechnik, Wasseraufbereitung, Wasserversorgung, Landwirtschaft, Heizungs- und Klimatechnik
Anwendungsgebiete
- Umkehrosmose, Filteranlagen, Ultrafiltration
- Waschanlagen allgemein, Teilewaschanlagen, Entfettungsanlagen (Metallbearbeitung), Spülanlagen(Großküchen, Getränkeindustrie)
- Wasserförderung, Druckerhöhung allgemein, Druckerhöhung in Wohn- und Geschäftsgebäuden
- Beregnungssysteme, Bewässerungstechnik
Market sectors
civil, agricultural, light Industry, water treatment, heating and air conditioning
Market sectors
- Handling of water,free of suspended sollds,ln the civil, Industrial and agricultural sectors
- Pressure boosting and water supply systems
- Irrigation systems
- Wash systems
- Water treatment plants
- Handling of moderately aggressive liquids, demineralized water,water and glycol,etc.
- Circulation of hot and cold water for heating,cooling and conditioning systems
- Boiler feed
Specifications Pump
The SV pump is a non-self priming vertical multistage pump coupled to a standard motor. The liquid end,located between the upper cover and the pump casing,is held in place by tie rods.The pump casing is available with different configurations and connection types.
- Delivery:up to 120 m3/h.
- Head:up to 330 m.
- Temperature of pumped liquid:
- -30 °C to 120 °C for SV 2,4,8 and 16,standard version
- Maximum operating pressure :
- SV 2,4,8 with oval flanges: 16 bar (PN 16)
- SV 2,,4,8,16 with round flanges or Victaulic: 25 bar (PN 25)
- SV2,,4,8,16 with Clamp connections:16 or 25 bar (PN 16 or PN 25)depending on the number of stages
- SV 33,,46:16,25,40 bar (PN16, PN25 or PN40)
- SV 66,92:16,25 bar (PN16,PN25)
- Tested in compliance with ISO 9906
- Direction of rotation:clockwise looking at the pump from the top down (marked with an arrow on the adapter and on the coupling).
Motor
- Squirrel cage in short circuit, aluminium casing,enclosed construction with external ventilation
- Standard supply motors up to 7.5 kW (included)for the 4-pole version,and up to 22 kW (included) for the 2-pole version.Other motor brands for higher powers
- The surface motors have efficiency values that fall within the range normally referred to as efficiency class 2
- IP55 protection
- Class F insulation
- Performances according to EN 60034-1
- Standard voltage:
- Single-phase version:220-240 V, 50 Hz.
- Three-phase version:220- 240/380-415 V,50 Hz for power up to 3 kW,
380-415/660-690 V,50 Hz for power above 3 kW
Materials
- Suitable for handling potable water (WRAS certified)
Konstruktionsmerkmale Pumpe
Die SV Pumpe Ist eine nicht selbstansaugende, mehrstufige vertikale Pumpe mit einem Standardmotor. Die Hydraulikeinheit ist mit Zugstangen zwischen dem Kopfstück und dem Pumpenfuß verspannt. Das Pumpengehäuse ist in verschiedenen Ausführungen und mit unterschiedlichen Anschlüssen erhältlich.
- Fördermenge: bis 120 m3/h
- Förderhöhe: bis 330 m
- Temperatur des Fördermediums: -30° C bis +120° C (Standard)
- max. Betriebsdruck:
- SV 2, 4, 8 mit Ovalflansch: 16 bar (PN 16)
- SV 2, 4, 8, 16 mit Rundflansch oder Victaulic®-Anschluss: 25 bar (PN 25)
- SV 2, 4, 8, 16 mit Clamp-Anschluss: 16, 25 bar (PN 16, PN 25), abhängig von der Stufenanzahl
- geprüft gemäß ISO 9906
- Drehrichtung im Uhrzeigersinn (Pumpe von oben betrachtet, Pfeilmarkierung auf dem Pumpengehäuse und der Kupplung)
Motor
- geschlossener, oberflächengekühlter Käfigläufer-Asynchronmotor
- Standardmotor bis einschließlich 22 kW bei 2poligen Motoren und bis einschließlich 7,5 kW bei 4poligen Motoren, für höhere Leistungen werden Fremdfabrikate eingesetzt
- die Motoren entsprechen standardmäßig der Energieeffizienzklasse 2
- Schutzart: IP 55
- Isolationsklasse: F
- Leistungen gemäß EN 60034-1
- Standardspannung
- Wechselstrom: 220-240 V, 50 Hz
- Drehstrom:
220-240/380-415 V, 50 Hz für Leistungen bis 3 kW 380-415/660-690 V, 50 Hz für Leistungen über 3 kW
Werkstoffe
- geeignet zur Förderung von Trinkwasser (WRASZertifizierung)

pageCatalog pdf di En 2012-05-22-30