Text version of the page
LINE SEIKIBIDIRECTIONAL PRESET COUNTERwith BCD OUTPUTMDR Series (Preset-BCD) Catalog - 23163 MDR SERIESMDR244MB MDR166MBDIN 72X144 SIZEBCD OUTPUTBRIGHT LARGE LED DISPLAY (4 or 6 DIGITS)1 or 2 PRESET LEVELSEASY PRESETTING BY THUMBWHEEL SWITCHWITH MEMORYMODEL SELECTIONSPECIFICATIONS144MBMDR 244MBMDR 166MBMDR 266MB644664461 ~ 9999991 ~ 99991 ~ 99991 ~ 999999Preset Digits21Preset LevelPreset RangeMemoryOptionBCDOUTPUT950 g1050 gWeightDigits Remote reset (100msec min.)Auto reset : One-shot reset (Output relay - 0.1~3sec reset)Output TypeOutput DisplayOutput TimeTurns ON during output timeContact output : Relay Type 1C (AC230V, 2.5A max. load)Non-contact output : NPN open collector (DC45V, 100mA maximum)One-shot mode: 0.1~3sec (adjustable)Overrun mode: Infinite 144MBMDR 166MBMDR 244MBMDR 266MBInput Method / SignalMake (Duty)Count ModeCount SpeedPulse Width ResetDC12V 100mA maximumE²PROM (10 yrs. retention, 10,000 times)MemoryPower Source for Sensor5kInput Impedance45 ~ 85%RH (Non-condensing)0 ~ 40°C (Non-freezing)Approximately 5.5VAAC100/110V or AC200/220V ±10%, 50/60 HzAC1500V (1 minute)Power SourcePower ConsumptionOperating TemperatureOperating HumidityHi-pot Test20M min. (DC500V megger)M3 Terminal Screw / BCD Output Terminal: D-SUB25 Pin ConnectorDielectric TestConnection Models ModelsMDR DisplayRed LED, 14.22 8.13mm (Zero Supress)1:1Contact Input : 25 msec min. / Non-Contact Input : 100 sec min.90°Quadrature (directional) / Add/SubtractContact Input : 20 Hz max. / Non-Contact Input : 5000 Hz max.Contact Input : Relay, MicroswitchNon-Contact Input : L: 0~1V ; H: +4.5~27VMDR |
|