Temperature
Temperature Profile of XDO System Temperature Profile of XDV System „Fc
95 / 35 86 / 30 77 / 25 68 / 20 60 / 16
The Liebert XD Units Enhance The Hot Aisle/Cold Aisle Approach
The XDO and XDV fill the cold aisle with air at the temperature required for proper operation of the electronic equipment.
Side views of Computational Fluid Dynamics (CFD) by Fluent.
Closed Architecture
Space-Saving
In-Row Cooling
Solution That Cools
That's Right In Line
A Specialized Rack
From The Top
With Your Needs
Cooling Solution
Liebert XDK
The Liebert XDV Cooling Module mounts vertically above or on the IT rack enclosure, drawing hot air from inside the cabinet or from the hot aisle. It then cools the air and discharges it down to the cold aisle. This space-saving solution requires zero floor space.
The modular Liebert XDH Horizontal Row Cooler is placed directly in line with rack enclosures. Air from the hot aisle is drawn in through the rear of the unit, cooled, and then discharged through the front of the unit into the cold aisle. The modular and adaptive design of the Liebert XDH allows it to be easily added as the demand for cooling increases.
Liebert XD CoolFrame™ module is specially designed to attach directly to the rear of the Egenera BladeFrame EX system. The Liebert XD CoolFrame allows these racks to be placed in a data center environment around other heat-generating equipment without adding to the heat load in the room. Use of the Liebert XD CoolFrame solution can promote efficient expansion of data center capacity with a minimal impact on your critical infrastructure.
These high heat density server racks utilize Liebert XD pumped refrigerant and closed architecture. The server heat load is dissipated into the cooling system through a heat exchanger in the bottom of the rack. Redundant high­performance fans drive closed loop air circulation in the rack's interior, while servers are supplied with cold air at the front of the rack. This keeps the dissipated heat from being expelled as an additional load on the IT room as is usually the case
Liebert XDV
Liebert XDH
Liebert XD CoolFrame
XDK
(Coming Soon)