Text version of the page
Text version of the page
COMPACT plus /AS-i ROBUST 42, 44/AS-i ASM1, ASM1E ASKM1 Type 4 transceiver withmuting and AS-i Type 4 transceiver with
integrated AS-i interface AS-i Safety monitor cat. 4 AS-i coupling module forsafety sensors COMPACT plus /AS-i, the muting solution for AS-Interface ROBUST/AS-i, like its name says: robust and economical ASM1, the safety upgradefor your AS-Interface ASKM1, the IP67 connectionmodule for safety switchesand sensors. Info 20 Info 21 Info 22 Info 23 •Integrated AS-i interface thatpermits a direct bus line con-nection•Bus address assignment withthe AS-i addressing device•Muting sensors, muting indi-cator can be connected right
onto transceiver •COMPACT •Integrated AS-i interface that permits a direct bus lineconnection •M12 connection for busaddress assignment with the
AS-i addressing device •Low power consumption thatpermits power supply via the
AS-i cable•High availability even underextreme environmental
conditions guaranteed by a
enclosure rate of IP 67,temperature range from –25°to +55°and an integrated lens heating system •AS-i wiring only on one side ofthe protective field (transceiver
contains transmitter and recei-
ver, passive deflecting mirror on
other side of protective field) •Surveillance of safety-relatedAS-i Safety sensor data traffic•EMERGENCY STOP switchingdevice with STOP0 / STOP1
function in accordance with
EN 60204-1•Safety class 4 in accordancewith EN 954-1•Sensors can easily be freelyassigned to the release
circuits on the output end via
the convenient Windows user
interface•ASM1/1 with one, ASM1/2 withtwo independent release
circuits,each with two channels•SERVICE button to automati-cally integrate (teach-in) AS-i
sensors into the system when
sensors are replaced•Housing width 45 mm •Secure AS-i Slave (bus station)with 2 secure inputs•Option for connecting safetyswitches in accordance with
Category 2, 3, 4 (EN 954-1)•Option for connecting safetylight barriers of type 4 with
relay outputs•Led displays for ASi status,inputs•AS-i addressing via integratedaddressing socket•M12 sensor connectionmethod•Bus cable contacting based onAS-i penetration method•Fastening plate for cap rail andscrew mounting plus muting with 4 different operating modes•Electrical wiring only on oneside of the protective field
(transmitter and receiver inone housing, deflecting mirroron other side of the protective
field)•External muting sensor module(optional), EMERGENCY
STOP push button or safety
switch can be connected•Plug-in parameter module Important technical data: Important technical data: AS-i safety monitor models ASM1/1 AS-i Safety monitor, 1 release circuit
ASM1/2 AS-i Safety monitor, 2 release circuits
ASM1E/1 AS-i Safety monitor withadditional functions, 1 release circuitASM1E/2 AS-i Safety monitor with
additional functions, 2 release circuits Important technical data: Safety type in accordance with IEC 61496: Safety type in accordance with IEC 61496: Safety type in accordance with IEC61496: Type 4 Type 4 Type 4 Number of beams: 2 Number of beams: 2, 4 Inputs: 2 inputs for safety sensorswith output contacts Range (m): 0,8 – 6 (with PM 2V) Range (m): 0,5 – 8 / 0,5 – 50 Beam distance (mm): 500 Beam distance (mm): 500, 300 Protection type: IP 67 Functions: Muting override andadditional functions via the AS-i Safety monitor Functions: Automatic restart,additional functions via the AS-i Safety monitor Connection method: M12 for sen-sors, penetration method for AS-i
cable > Typical areas of application Typical areas of application Typical areas of application Typical areas of application Access protection with mutingfunction at the entry and exit of
automated industrial production cells
networked with AS-i in conveyor manufacturer
technology, automobile manufac-
turing and palletizing equipment. Access protection aroundequipment for storage and
conveyor systems, palletizing
equipment and machines from the wood, ceramics and
stoneware industries with AS-i networks. To monitor safety-related AS-iSafety bus nodes such as
EMERGENCY STOP command
devices, light curtains, multi-
beam light barriers, industrial laser scanners or safety door inter-
locks at the AS-Interface. Connecting safety sensors withoutput contacts, for example
industrial safety switches to monitor guard
doors or optoelectronic safety equipment with relay outputs to
AS-i Safety. AS-i Safety accessories •ASM1-SWC Safety monitorstart-up kit •APG-01 programming devicefor entering slave bus adresses 13
|