Group: Nidec
Catalog excerpts
LSHT - Aluminium frame FLSHT - Cast iron frame
Open the catalog to page 1FLSHT DIMENSIONS HELP WITH SELECTION LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c 3
Open the catalog to page 3LSHT-FLSHT Induction motors for smoke extraction General information Introduction In this catalogue, Nidec describes the LSHT and FLSHT range of 3-phase induction safety motors for smoke extraction ventilation applications. All our smoke extraction motors have been designed for mixed use: - operation in continuous duty at an ambient temperature (when operating in comfort mode) - use for a limited time at high temperature in the event of fire (when operating in safety mode) These motors, adapted to European safety standards, are designed to be fitted on fans that are incorporated in smoke...
Open the catalog to page 5LSHT-FLSHT Induction motors for smoke extraction General information Quality commitment Nidec's quality management system is based on: - Control of procedures right from the initial sales offering until delivery to the customer, includingdesign, manufacturing start-up and production - A total quality policy based on making continuous progress in improving operational procedures, involving all departments in the company in order to give customer satisfaction as regards delivery times, conformity and cost - Indicators used to monitor procedural performance - Corrective actions and...
Open the catalog to page 6LSHT-FLSHT Induction motors for smoke extraction General information Quality assurance - Certification EN 12101-3 SMOKE EXTRACTION As of 2005, European legislation states that all motors fitted on fans designed to extract smoke, whether in covered car parks, tunnels or public buildings, must display the CE mark as a proof of compliance with European standard EN12101-3. This compliance of our whole range of smoke extraction motors has been verified during fire resistance tests conducted on load testing benches or fans by various approved laboratories certified at European level. Our smoke...
Open the catalog to page 7LSHT-FLSHT Induction motors for smoke extraction General information Quality assurance - Certification 3-phase TEFV induction motors, for continuous operation at ambient temperatures, and for emergency operation at high temperatures for a specified length of time (dual purpose). They have been adapted to European safety standards for smoke and heat extractor fans in the event of fire (smoke extraction). Motors with aluminium frame Type 8 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 8LSHT-FLSHT Induction motors for smoke extraction General information Designation The complete motor reference described below will enable you to order the desired equipment. The selection method consists of following the terms in the designation. Series designation Housing designation and manufacturer code Rated power Temperature class Mains voltage Mains frequency LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c 9
Open the catalog to page 9LSHT-FLSHT Induction motors for smoke extraction General information Description 10 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 10LSHT-FLSHT Induction motors for smoke extraction Construction Mounting arrangements Foot mounted motors * all frame sizes IM 1001 (IM B3) - Horizontal shaft - Feet on floor IM 1071 (IM B8) - Horizontal shaft - Feet on top IM 1051 (IM B6) - Horizontal shaft - Wall mounted with feet on left when viewed from drive end IM 1061 (IM B7) - Horizontal shaft - Wall mounted with feet on right when viewed from drive end IM 1031 (IM V6) - Vertical shaft facing up - Feet on wall (FF) flange mounted motors * all frame sizes (except IM 3001 limited to frame size 225 mm) IM 2001 (IM B35) - Horizontal...
Open the catalog to page 11LSHT-FLSHT Induction motors for smoke extraction Construction Mains connection TERMINAL BOX VERSION Placed as standard on top of the motor near the drive end, it is fitted with one or more metal cable glands. The standard position of the cable gland is on the right, seen from the drive end but, owing to the symmetrical construction of the box, it can usually be placed in any of the 4 directions, as per table 1. If required, the terminal box may be fitted in a different position (on the left or right as seen from the drive end, and at the DE or NDE of the motor housing). Positions of the...
Open the catalog to page 12LSHT-FLSHT Induction motors for smoke extraction Construction Mains connection COVER PLATE VERSION with FLYING LEADS (SINGLE-CORE CABLES) Motors can also be supplied with flying leads consisting of single-core cables (as an option, the cables can be protected by a plastic-coated metal sheath). Please state cable characteristics (length, number of conductors*) and the cable outlet position, as per the table. the cables exit on top of the motor the cables exit at the motor sides Frame sizes Frame sizes Single-speed motors YA arran9ed as 6+1 <flarth) Two-speed motors arranged as 6+1...
Open the catalog to page 13LSHT-FLSHT Induction motors for smoke extraction Construction Cooling Enclosed machine. Smooth or finned casing. No external fan. Ventilation provided by air flow coming from the driven system. Enclosed machine. Smooth or finned ventilated casing. External shaft-mounted fan. 14 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 14LSHT -Aluminium frame Induction motors for smoke extraction Electrical characteristics 200°C/120 min - 2 poles - 3000 min1 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c 15
Open the catalog to page 15LSHT -Aluminium frame Induction motors for smoke extraction Electrical characteristics 200°C/120 min -4 poles -1500 min1 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 16LSHT -Aluminium frame Induction motors for smoke extraction Electrical characteristics 200°C/120 min - 6 poles -1000 min1 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 17LSHT -Aluminium frame Induction motors for smoke extraction Electrical characteristics 200°C/120 min - 8 poles - 750 min'1 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 18LSHT -Aluminium frame Induction motors for smoke extraction Electrical characteristics 200°C/120 min - 2/4 poles - 3000/1500 min'1 LSHT - FLSHT induction motors for smoke extraction - 5026 en-2017.09/c
Open the catalog to page 19All LEROY-SOMER catalogs and technical brochures
-
FFB brake motors
52 Pages
-
Brake motors range
16 Pages
-
POULIBLOC
8 Pages
-
Multibloc
2 Pages
-
DYNABLOC
100 Pages
-
MULTIBLOC - IMfinity
88 Pages
-
Cb, Ot, Mub, Mb, FFB
84 Pages
-
LS FFB - LSES FFB
52 Pages
-
IMfinity® ATEX induction motors
16 Pages
-
LSK
164 Pages
-
asynchrones triphasés
176 Pages
-
INDUCTION MOTORS
60 Pages
-
Powerdrive MD2 & Systemiz
2 Pages
-
Industrial Refrigeration
16 Pages
-
Energy Efficiency Solutions
24 Pages
-
Proxidrive
2 Pages
-
Digistart D3
8 Pages
-
Multibloc
2 Pages
-
Training Courses 2018
52 Pages
-
Environmental Policy
2 Pages
-
Express Availability Commitment
12 Pages
-
LEROY-SOMER QUALITY POLICY
2 Pages
-
Port Logistics
20 Pages
-
Hydroelectricity
2 Pages
-
Nuclear Applications
16 Pages
-
Electromechanical drive systems
20 Pages
-
Marine Applications
20 Pages
-
Minerals Industry
12 Pages
-
LEROY-SOMER DRIVE SOLUTIONS
1 Pages
-
Crane and hoist solutions
16 Pages
-
Unimotor
2 Pages
-
LC liquid cooled motors
92 Pages
-
Induction motors for axial fans
60 Pages
-
3-phase induction motors
176 Pages
-
Geared motors 3000 Range
16 Pages
-
IMfinity® induction motor range
20 Pages
-
FFB brake motors
24 Pages
-
TAL 040 - TAL 042 - TAL 044
36 Pages