General
Listof abbreviations
[°]Angle of action of radial force M >
B [Nm]Braking torque of brake [%]Mechanical efficiency M >
stall [Nm]Stall torque of motor >
A [%]Mechanical start-up efficiency ofgearbox M >
L [Nm]Load torque M >
r [Nm]Rated torque >
c=1 [%]Gearbox efficiency with c=1 M >
V [Nm]Deceleration torque >
G [%]Gearbox efficiency -Ratio step n >
1 [rpm]Inputspeed n >
2 [rpm]Outputspeed AC -Alternating current/voltage n >
L [rpm]Load speed >
1
n >
r [rpm]Rated speed c -Load capacity of geared motors cos -Power factor of motor OT [min]Operating time DC -Directcurrent/voltage P >
1 [kW]Inputpower d >
w [mm]Effective diameter of transmission element P >
1 perm [kW]Permissible inputpower P >
B 20Ëš [W]Power of brake coil at20ËšC P >
req [kW]Required inputpower f -Effective direction factor atoutputshaft P >
r [kW]Rated power F >
a [N]Applied axial force F >
a Tab [N]Table value of axial force Q [J]Friction energy per switching cycle F >
a perm [N]Permissible axial force Q >
BW [J]Friction energy of brake until readjustment f >
r [Hz]Rated frequency F >
r [N]Applied radial force Q >
E [J]Maximum permissible braking energy forone-time switching operation F >
r Tab [N]Table value of radial force F >
r perm [N]Permissible radial force Q >
perm [J]Permissible friction energy per switchingcycle f >
w -Load application factor atoutputshaft f >
z -Additional radial force factor of transmission element S >
B -Brake safety factor S >
h [h >
-1 ]Operating frequency h [m]Site altitude amsl S >
h, perm [h >
-1 ]Permissible operating frequency S >
hü [h >
-1 ]Transition operating frequency i -Ratio I >
A [A]Motor starting current t >
11 [ms]Delay time on engagement I >
B [A]Rated brake current t >
3 [ms]Slipping time I >
r [A]Rated current t >
B [ms]Braking time T >
amb [ËšC]Ambienttemperature J >
D [kgm >
2 ]Momentof inertia of the drive reduced onthe inputshaft U >
r [V]Rated voltage J >
B [kgm >
2 ]Momentof inertia of the brake U >
mains [V]Mains voltage J >
G [kgm >
2 ]Momentof inertia of the gearbox reducedon the inputshaft Z >
a -Number of switching operations until readjustment J >
L [kgm >
2 ]Momentof inertia of the load J >
LD [kgm >
2 ]Momentof inertia of the load reduced onthe inputshaft CCC Certificate for China compulsory productcertification J >
M [kgm >
2 ]Momentof inertia of the motor J >
Z [kgm >
2 ]Additional momentof inertia CE Communauté Européene CSA Canadian Standards Association k -Application factor (according toDIN 3990) DIN Deutsches Institutfür Normung EMC Electromagnetic compatibility k >
h -Power correction factor of site altitude EN European standard k >
l -Intensity of gearbox load capacity IEC International Electrotechnical Commission k >
L -Power correction factor of operating mode IM International Mounting Code k >
Tamb -Power correction factor ambienttemperature IP International protection code NEMA National Electrical Manufacturers Association m [kg]Mass UL Underwriters Laboratory listed component M >
1 [Nm]Inputtorque UR Underwriters Laboratory recognisedcomponent M >
2 [Nm]Outputtorque M >
2 perm [Nm]Permissible outputtorque USDA United States Departmentof Agriculture M >
A [Nm]Motor starting torque VDE Verband deutscher Elektrotechniker >
G-motion consten 7/2006 1-5 >