| Brake units - Please note: - The assignments listed in the table for the external brake resistors permit a maximum braking time of up to 15 seconds - The relative duty time of 10% for a maximum of 15 seconds - The reference variable for the assignment is the set permanent power of the device. - Although a higher brake power can be achieved by using other resistors or by connecting a number of resistors in parallel or series, the resistance value must not fall below the minimum specified. - All brake resistors listed have integrated temperature monitoring with potential-free alarm contact for switching off the mains contactor. |