Design - 8200
Ratings
Frequency inverter for three-phase mains connection at 150% overload
Type82258226 8227 Order ref.EVF8225-EEVF8226-EEVF8227-E Order ref. 8200 HVAC and pump driveEVF8225-EEVF8226-EEVF8227-E -V020-V020-V020 Mains voltageU >
M [V]320 V... 528 V ±0 % ; 45 Hz ... 65 Hz ±0%Alternative DC supplyU >
DC [V]460 V... 740 V ±0% Data for operation on mains: 3 AC / 400 V / 50 Hz / 60 Hz Motor power (4-pole ASM)P >
r [kW]55.075.090.0Output currentI [A]110.0150.0180.0Max. output current 60 sI >
max [A]165.0225.0270.0Output powerS >
r [kVA]76.2103.9124.7 Data for operation on mains: 3 AC / 480 V / 50 Hz / 60 Hz Motor power (4-pole ASM)P >
r [kW]75.090.0110.0Output currentI [A]105.0142.0162.0Max. output current 60 sI >
max [A]157.0213.0256.0Output powerS >
r [kVA]91.4124.0149.0Mains current I >
r [A]100.0135.0165.0Power lossP >
loss [W]147019602400Chopper frequency Adjustable 4 kHz, 8 kHz, 12 kHz, 16 kHzField frequencyResolution 20 mHz absoluteAccuracy
Digital setpoint preselection±0.05 HzAnalog setpoint preselection
- Linearity±0.5% (reference fmax)- Temperature sensitivity 0...40°C + 0.4 % - Offset ±0 % Dimensions[mm]a340 x450 x450 xb591 x680 x680 xe285285285Weightm [kg]36.559.059.0 >
ae
b 30
Lenze