Design - 8200
Ratings
Type8201820282038204Order ref.EVF8201-EEVF8202-EEVF8203-EEVF8204-EOrder ref.EVF8202-Ecompact device-V002 Mains voltageU >
M [V]1 / N / PE / AC / 230V / 50 Hz / 60 Hzpermissible range190...260 V ±0% / 45...65 Hz ±0%Alternative DC supplyU >
DC [V]270 V...360 V ±0%Output voltage Motor power 4-pole ASMkW0.370.751.502.20
Output currentA2.64.07.09.5
Max. output current 60 sA3.96.010.514.2
Output powerkVA1.01.52.73.6
Mains r.m.s. current >
1) 3 / PE / AC / 0...U >
mains / 0...50 Hz , up to 240 Hz as an option Data for operation on mains: 1 AC / 230 V / 50 Hz / 60 Hz >
2) Without mains choke/filter A5.09.015.0–With mains choke/filter 4.27.512.517.0Power lossW305070100
Chopper frequency Up to 9.2 kHzField frequencyResolution 50 mHz absoluteAccuracy
Digital setpoint preselection±0.05 HzAnalog setpoint preselection
- Linearity±0.5% max. selected- Temperature sensitivity 0...40°C + 0.4% signal level - Offset ±0.3% 5 V or 10 V Dimensionsa mm64648383b 180180250250e 158198 (158)211211Weightkg1.01.32.22.2Weight (compact device)1.0 >
1) With mains choke/filter: Max. output voltage = approx. 96% of mains voltage >
2) Take the N-conductor load into account if the mains power is being distributed symmetrically on a number of inverters! >
ae
b Lenze