Design - 8200 and 9300 vector
Selecting a drive system
Sequence diagram
Calculate the inverter powerP 2.2 kWP 2.2 kW Select single-phase or 3-ph. inverter Select 3-ph. inverter >
No
Yes
Yes
Yes Wall mounting? supplied Select alternative
mounting line protectionFuse
Industrial circuit breaker >
No Reduce the mains current? Select mains choke or mains filter
Rfi filter?Class A Class B >
No Select RFI filter or mains filter Select RFI filter and mains choke or mains filter Motor cable< 50 m shielded or 50 to 100 m shielded or 100 m to 200 m shielded < 100 m unshielded 100 to 200 m unshielded 200 m to 400 m unshielded Longer motor cable Select motor filter Select sinusoidal filter Contact Lenze Braking on short ramps or with high mass moment of inertia >
No Select brake chopper and brake resistor or supply/regenerative feedback module Determine the type of operation/controlControl via terminalsControl via terminalsControl and parameter setting Parameter setting via operating moduleParameter setting via wiring systemvia host system Select potentiometer and Select potentiometer and Select
fieldbus moduleoperating module fieldbus module Enter data into order form 14 >
Lenze