■ Electronic Pressure standard LPC 200 • pp o/\/\
L. IX"LCf/ Accuracy ±0,025% f.s., max. 58 000 PSI LrU ZUU
Electronic Pressure Professional calibrator LPC 200, changeable industrial pressure sensors
• Very simple operation, easily-read display (backlighting selectable)
• Changeable reference sensors (plug & play) this means, up to 10 pressure ranges with one instrument
• Ranges from 0...5.8 psi (400 mbar) up to 0...58000 psi (4000 bar) (also vacuum-, compound- and absolute pressure ranges)
• Accuracy up to ±0.025% f.s. resp. 0.1% of reading
• Logging function, pressure rate, min-/max value, Bargraph, Tare
• Issue calibration certificates with optional PC-Windows®-software LPC-Cal
• Pressure calibration kit's, complete with calibration manufacturer of hand pumps as portable pressure source
• Chargeable Lithium-Ion battery, incl. Charger, USB-interface
• Switchable pressure unit PSI, bar, mbar, kPa, mmHg, inHg
Together with a suitable calibration pressure source like the calibration hand pumps LPP 30 (pneumatic) or LPP 700 / LPP 1000 (hydraulic), the LPC 200 offers a pecision pressure calibration system, suitable also for use on site, portable. The LPC 200 also opens up other helpful applications, e.g. recording of pressure curves (logging function), leak testing (pressure rate function). These useful functions can be easily activated or deactivated by pressing the respective keys. A factory calibration certificate for each reference sensor certifies the total uncertainty of the measuring chain. Alternatively, on request, a DKD calibration certificate can be
supplied.
Using the optional LPC-Cal software, the logged data, stored in the LPC 200, can be transferred to a PC via a USB connection, where it can be stored in an Excel® file for documentation and further evaluation. In addition, LPC-Cal offers the possibility of PC-supported calibration of pressure measuring instruments using the LPC 200.
Technical Data (Indicator LPC 200 together with reference sensor LPC-2):
Standard Pressure Ranges (PSI) Standard Pressure Ranges (bar)
5.8 23.2 87 0.4 1.6 6
232 580 1450 3626 8700 14500
16 40 100 250 600 1000
Overpressure safety (bar)
2 10 35
80 80 200 500 1200 1500
Burst pressure (bar)
2.4 12 42
96 400 800 1200 2400 3000
Accuracy
(Total uncertainty of measurement chain)
0.025% FS or 0.1% of measured value (whichever is the greater), calibrated at 23°C and in vertical mounting position with pressure conn. facing down.
High Pressure Ranges (PSI) High Pressure Ranges (bar)
23200 36200 58000 1600 2500 4000
Overpressure safety (bar)
2000 3000 4400
Burst pressure (bar)
4000 5000 7000
Accuracy
(Total uncertainty of measurement chain)
0.15% FS (calibrated at 23°C and in vertical mounting position with pressure conn. facing down.)
Type of pressure
see above (standard and high pressure ranges)
but also vacuum-, compound- and absolute pressure ranges
Units of pressure
bar, mbar, kPa, mmHg, inHg, PSI (depending on range, switchable)
Active temperature compensation
+10...+40°C
Permissible ambient temperature
0...+50°C
Traceable factory certificate of calibration (optional: DKD certificate of calibration)
Calibration
DRUCK & TEMPERATUR Leitenberger GmbH
Bahnhofstr. 33 • D-72138 Kirchentellinsfurt • Germany
Tel.: +49 - 71 21 - 9 09 20 - 0 • Fax: +49 - 71 21 - 9 09 20 - 99
E-Mail: DT-Export@Leitenberger.de • http://www.druck-temperatur.de
Technische Änderungen vorbehalten. Freibleibend • (Rel. 080619) • All technical modifications reserved. Without engagement
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
pdf-page pdf di En 2008-12-49-05