Catalogue Welding roofing membranes
www.leister.com
print switch display
Page / 9
Where to buy
this product ?
Request
a Quote
LEISTER Process Technologies - 16513, 208315, 81029, 68351
/ 9
See other catalogues for LEISTER Process Technologies
Text version of the page
VARIMAT V used for overlap wel- TRIAC DRIVE PID used for welding X84 used to weld an under-roof TRIAC PID with a 20 mm wide slot ding of plastic roofing membranes. plastic roofing membranes in a liner on a high-pitched roof. nozzle manufacturer and pressure roller used to
light dome. Weighing only 6.1 kg, the X84 weld plastic roofing membranes.
copes with any incline at constant
speed.
Hand tool
TRIAC PID
Thanks to micro-processor controlled temperature and electronic monitoring. The preferred hand tool for welding with high quality.
Hand tool
TRIAC S
TRIAC S: the reliable, cost-effective and proven hand tool with steplessly controlled temperature range.
"Er""
Adaptor tube with heat protection Electronic industrial heating element protection Motor shut-off at minimal carbon level Multiple replacement of carbon industrial brushes possible Suitable for continuous operation
Reproducible results thanks to digital display of set and actual temperature
Welding results independent of voltage fluctuations and
ambient temperature
Adaptor tube with heat protection
Electronic heating element protection
Motor shut-off at minimal carbon level
Suitable for continuous operation
Multiple replacement of carbon brushes possible
Technical Data
Voltage
V~
42 100 120 200 230
Power consumption
W
1000 1400 1600 1400 1600
Frequency
Hz
50 / 60
Temperature
°C
50 - 600
Air flow (20°C)
l/min
230
Pressure static
Pa
ca. 3000 (30 mbar)
Noise emission level LpA
dB
65
Size (L x 0)
mm
340 x 90, handle 0 56
Weight
kg
1.4 (with 3 m cord)
Marking of conformity
2
Approval mark
3
Certification scheme
CCA
Protection class II
0
Technical Data
Voltage
V~
42 100 120 200 230
Power consumption
W
1000 1400 1600 1400 1600
Frequency
Hz
50 / 60
Temperature
°C
20 - 700
Air flow (20°C)
l/min
230
Pressure static
Pa
ca. 3000 (30 mbar)
Noise emission level LpA
dB
65
Size (L x 0)
mm
340 x 90, handle 0 56
Weight
kg
1.4 (with 3 m cord)
Marking of conformity
2
Approval mark
3
Certification scheme
CCA
Protection class II
0
6
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
pdf-page pdf di En 2008-11-47-22