LHS 40: The hot mid-range models.
The «40» design line operates within the power range 2 - 4 kW. They are available as single-phase versions in the voltage range 100 - 230 V and also as the three-phase version 40L for the voltage range 3 x 230 to 3 x 440 V Air inlet and air outlet connections are compatible with the predecessor heater type LE 3300 and its accessories.
LHS CLASSIC 40S / 40L
Air heater Air heater
LHS PREMIUM 40S / 40L LHS SYSTEM 40S / 40L
Technical data
LHS40S / 40L
CLASSIC PREMIUM
SYSTEM
Max. air outlet temperature °C
600 650
650
Min. air flow acc. to graph page 9
Max. air inlet temperature °C
80 80
80
Max. ambient temperature °C
65 65
65
Weight g 40S
850 850
850
40L
950 950
950
Mark of conformity
C€C€C€
Approval mark
®®|®
Certification scheme
CCA CCA
CCA
Protection classe II
Combination possibilities
- Leister air heater at maximum heat power and without nozzle with Leister industrial blower at 50 Hz, 1.5 m hose length and unimpeded air outflow.
- Hot-air temperature 3 mm after air outlet, measured at the hottest point.
- Air flow in Nl/min = standard litres / min compliant with DIN 1343.
Blower Type
Number LHS 40S x Power consumption kW
LHS 40S
Air flow Nl/min
LHS 40S
Temperature °C
ROBUST
1 x 2.0
1 x 840
200
ROBUST
2 x 2.0
2 x 480
300
ROBUST
4 x 2.0
4 x 250
450
ROBUST
1 x 4.0
1 x 810
370
ROBUST
2 x 4.0
2 x 470
540
SILENCE
1 x 2.0
1 x 510
280
SILENCE
2 x 2.0
2 x 460
290
SILENCE
4 x 2.0
4 x 380
300
SILENCE
1 x 4.0
1 x 440
600
SILENCE
2 x 4.0
2 x 410
600
SILENCE
4 x 4.0
4 x 330
600
ASO
4 x 2.0
4 x 500
230
ASO
4 x 4.0
4 x 480
450
Blower Type
Number LHS40L x Power consumption kW
LHS 40L Air flow Nl/min
LHS 40L
Temperature °C
ROBUST
1 x 2.0
1 x 890
210
ROBUST
2 x 2.0
2 x 510
310
ROBUST
4 x 2.0
4 x 270
470
ROBUST
1 x 4.0
1 x 810
390
ROBUST
2 x 4.0
2 x 450
560
SILENCE
1 x 2.0
1 x 567
295
SILENCE
2 x 2.0
2 x 453
320
SILENCE
4 x 2.0
4 x 368
330
SILENCE
1 x 4.0
1 x 410
620
SILENCE
2 x 4.0
2 x 400
620
SILENCE
4 x 4.0
4 x 330
630
ASO
4 x 2.0
4 x 500
270
Air flow and tempe
of the hot-air syste Accessories or
rature specifications may d< m (nozzles, hose length, etc
i page 28
viate from ideal values
due to modifications
40S
Voltage V ~
100
120
200
230
Power consumption kW
2
2
2
4
2
4
CLASSIC Order no.
118.575
118.576
118.577
118.579
118.578
118.101
PREMIUM Order no.
125.872
125.873
125.874
125.876
125.875
125.877
SYSTEM Order no.
125.963
125.964
125.965
125.967
125.966
125.968
40L
Voltage V ~
3 X 230
3 X 400
3 X 440
Power consumption kW
2
4
2
4
2
4
CLASSIC Order no.
118.580
118.581
118.582
118.583
118.584
118.585
PREMIUM Order no.
125.578
125.881
125.879
125.882
125.880
125.883
SYSTEM Order no.
125.969
125.972
125.970
125.973
125.971
125.974
8
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
pdf-page pdf di En 2008-12-49-05