| | | LHS 40: The hot mid-range models. | | |
| | | |
| | | The «40» design line operates within the power range 2 - 4 kW. They are available as single-phase versions in the voltage range 100 - 230 V and also as the three-phase version 40L for the voltage range 3 x 230 to 3 x 440 V Air inlet and air outlet connections are compatible with the predecessor heater type LE 3300 and its accessories. | | |
| | | |
| | | LHS CLASSIC 40S / 40L | | Air heater Air heater LHS PREMIUM 40S / 40L LHS SYSTEM 40S / 40L | | |
| | | |
| | | | | | | | | | | Technical data | | | | | | LHS40S / 40L | CLASSIC PREMIUM | SYSTEM | | | | Max. air outlet temperature °C | 600 650 | 650 | | | | Min. air flow acc. to graph page 9 | | | | | | Max. air inlet temperature °C | 80 80 | 80 | | | | Max. ambient temperature °C | 65 65 | 65 | | | | Weight g 40S | 850 850 | 850 | | | | 40L | 950 950 | 950 | | | | Mark of conformity | C€C€C€ | | | | Approval mark | ®®|® | | | | Certification scheme | CCA CCA | CCA | | | | Protection classe II | | | | | | | | | | | | | | | | | | | | Combination possibilities - Leister air heater at maximum heat power and without nozzle with Leister industrial blower at 50 Hz, 1.5 m hose length and unimpeded air outflow. - Hot-air temperature 3 mm after air outlet, measured at the hottest point. - Air flow in Nl/min = standard litres / min compliant with DIN 1343. | | | | Blower Type | Number LHS 40S x Power consumption kW | LHS 40S Air flow Nl/min | LHS 40S Temperature °C | | | | ROBUST | 1 x 2.0 | 1 x 840 | 200 | | | | ROBUST | 2 x 2.0 | 2 x 480 | 300 | | | | ROBUST | 4 x 2.0 | 4 x 250 | 450 | | | | ROBUST | 1 x 4.0 | 1 x 810 | 370 | | | | ROBUST | 2 x 4.0 | 2 x 470 | 540 | | | | SILENCE | 1 x 2.0 | 1 x 510 | 280 | | | | SILENCE | 2 x 2.0 | 2 x 460 | 290 | | | | SILENCE | 4 x 2.0 | 4 x 380 | 300 | | | | SILENCE | 1 x 4.0 | 1 x 440 | 600 | | | | SILENCE | 2 x 4.0 | 2 x 410 | 600 | | | | SILENCE | 4 x 4.0 | 4 x 330 | 600 | | | | ASO | 4 x 2.0 | 4 x 500 | 230 | | | | ASO | 4 x 4.0 | 4 x 480 | 450 | | | | Blower Type | Number LHS40L x Power consumption kW | LHS 40L Air flow Nl/min | LHS 40L Temperature °C | | | | ROBUST | 1 x 2.0 | 1 x 890 | 210 | | | | ROBUST | 2 x 2.0 | 2 x 510 | 310 | | | | ROBUST | 4 x 2.0 | 4 x 270 | 470 | | | | ROBUST | 1 x 4.0 | 1 x 810 | 390 | | | | ROBUST | 2 x 4.0 | 2 x 450 | 560 | | | | SILENCE | 1 x 2.0 | 1 x 567 | 295 | | | | SILENCE | 2 x 2.0 | 2 x 453 | 320 | | | | SILENCE | 4 x 2.0 | 4 x 368 | 330 | | | | SILENCE | 1 x 4.0 | 1 x 410 | 620 | | | | SILENCE | 2 x 4.0 | 2 x 400 | 620 | | | | SILENCE | 4 x 4.0 | 4 x 330 | 630 | | | | ASO | 4 x 2.0 | 4 x 500 | 270 | | | | Air flow and tempe of the hot-air syste Accessories or | rature specifications may d< m (nozzles, hose length, etc i page 28 | viate from ideal values | due to modifications | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | | | 40S | | | | Voltage V ~ | 100 | 120 | 200 | 230 | | | | Power consumption kW | 2 | 2 | 2 | 4 | 2 | 4 | | | | CLASSIC Order no. | 118.575 | 118.576 | 118.577 | 118.579 | 118.578 | 118.101 | | | | PREMIUM Order no. | 125.872 | 125.873 | 125.874 | 125.876 | 125.875 | 125.877 | | | | SYSTEM Order no. | 125.963 | 125.964 | 125.965 | 125.967 | 125.966 | 125.968 | | | | | | | | 40L | | | | Voltage V ~ | 3 X 230 | 3 X 400 | 3 X 440 | | | | Power consumption kW | 2 | 4 | 2 | 4 | 2 | 4 | | | | CLASSIC Order no. | 118.580 | 118.581 | 118.582 | 118.583 | 118.584 | 118.585 | | | | PREMIUM Order no. | 125.578 | 125.881 | 125.879 | 125.882 | 125.880 | 125.883 | | | | SYSTEM Order no. | 125.969 | 125.972 | 125.970 | 125.973 | 125.971 | 125.974 | | | | | | | | | | | | | | | |
| | | |
| | | |
| | | 8 | | |
| | | |
| | | | | | | | | | | | | | | | | |