High temperature air heater Combination possibilities
LE10000 HT (up to 900°C)
- Leister air heater at maximum heat power and without nozzle with Leister blower at 50 Hz,1.5 m hose length and unimpeded air outflow.- hot-air temperature 3 mm after air outlet,measured at the hottest point.- Air flow in Nl/min = standard litres / min compliant with DIN 1343. Power TypNumber LE × Air flow Nl/minTemperature °C Power consumption ROBUST1 × 150001 × 1100 850 AS01 × 150001 × 2200 690 ASO2 × 150002 × 2100 700 AIRPACK1 × 150001 × 3400 340 AIRPACK2 × 150002 × 1650 620Air flow and temperature specifications may deviate from ideal values due to modificationsof the hot-air system (
nozzles,hose length,etc.). >
Technical dataHigh temperature LE 10000 HT Installation dimensions in mm
No integrated power electronics?
Industrial heating element tube with protective tube? Max.air outlet temperature °C900 Max.air inlet temperature °C100 Min.air flow l/min.830 Max.ambient temperature °C100 Weight kg4.0 Mark of conformity 2 Protection classe I 1 >
Optional power controller DSE three-phase controller (Page 23) Optional temperature regulation DSE three-phase controller and KSR DIGITAL temperature regulator (Page 22 /23)
Tube ø 90 Protection tube ø 103 Voltage V ~3 × 4003 × 480 Power consumption kW1515 Order no. >
110.568113.349 Accessorieson page 29 Additional versions on request
17 >