| | Response Time | <30 milliseconds | Electrical Fast | +/-1kV (power supply) | |
| | | | Transients (EFT) | +/-0.5kV (control signals) | |
| | Indicators | Run = Green LED | | | |
| | | Stop = Red LED | Restart Function | Selectable manual or automatic restart | |
| | | Mat Status = 4 Mat Activated Red LEDs | | Internal/Lockout restart and External/ | |
| | | 4 Mat Disconnected Yellow LEDs | | Remote restart available | |
| | | Relay Fault = Internal Yellow LED | | | |
| | | | Reset Function | Power-up and Relay Fault Reset internal | |
| | Operational | Selectable automatic restart and guard only | | manual push-button | |
| | Modes | modes | | | |
| | | | Enclosure | Steel (Powdercoat Machinery Black) | |
| | Power Input | 120 VAC (for 60Hz), 240 VAC (for 50 Hz) or | | 8" h x 6" w x 3.75" d | |
| | | 24 VDC | | (203 mm x 152 mm x 95 mm) | |
| | Rated Supply | 0.125AAC, 0.75 A DC | Enclosure Rating | NEMA12, IP65 | |
| | Current | | | | |
| | | | Mounting | Surface Mount | |
| | Safety Inputs | Screw clamp connections for up to four 4- | | | |
| | | wire safety mats with up to 40' cord length | Shipping Wt. | 11 lbs. | |
| | | each (quick disconnect mat connections | | | |
| | | also available) | Operating | 32oFto122oF | |
| | | | Temperature | (0o C to 50o C) | |
| | Safety Output | Two captive contact relays with two closed | | | |
| | Relays | when run (NO) and one open when run (NC) | Relative Humidity | Acceptable Range = 20-90% | |
| | | sets of contacts rated 8 amps at 230 VAC | | | |
| | | | Standards of | Designed to meet UL 508-1999 Standard for | |
| | Replaceable | Mechanical: 10,000,000 operations | Conformity | Industrial Control Equipment, ANSI B11.19- | |
| | Relay Pack Life | Electrical: 500,000 operations at 1 amp at | | 2003 Performance Criteria for | |
| | | 240 VAC | | Safeguarding, OSHA 1910.212-1996 | |
| | | | | General Machine Guarding, ANSI/RIA 15.06- | |
| | Electrostatic | +/-10kV (air discharge) | | 1999 Industrial Robots and Robots | |
| | Discharge (ESD) | +/-6kV (contact discharge) | | Systems-Safety Requirements, EN/IEC | |
| | | | | 60204-1998 Electric Equipment of Machines | |
| | Radiated RF | 10 volts/meter, 100 to 1,000 MHz | | and EN 1760-1998 Safety of Machinery, | |
| | Field | | | Pressure Sensitive Protective Devices | |
| | | | | | |