ο›š

As partial technical support for the MicroCure Tech-nology, Lambda offers process development and op- timization assistance to include process trials.The Lambda Technologies MicroCure 5100 is de-signed around the unique Variable Frequency Mi- crowave process technique for the selective, rapid, and uniform procesing of materials.

MicroCure 5100 In-Line System - 22060 5100

• • Rapid and selective heating when compared to conventional ovens Uniform energy distribution

Benefits

• Precise Process Cycle Control VFM processing has several specific advantages over other technologies: • Rapid sweep over controlled bandwidth allows processing of electronics packaging assemblies without arcing and circuit damage

Technical Specifications

Microwave Power:700, 1800 WattsFrequency Range:5.8 to 7.0 GHz,7.3 to 8.7 GHzSweep Rate Adjust:0.1 to 60 secondsTemperature Control:IR, Non-contact, to 385

System operating features include:

• Automated cycle control and data acquisition • • Pre-set process parameters, programmable for product type and quantity User-defined profiling event cycles • • • Characterization routines for materials/process optimization Auto Ramp Software - Provides acurate temp and ramp rate control IR Temp Monitoring System for closed loop feed back

°

CTemperature Monitor:Up to 4 channels, to 265

°

CCavity Size:13” H x 45” W x 18” DDimensions:60” H x 54” W x 41” DWeight:1500 lbs/680kg

Accessories and Options

• 4 Channel Fiber Optic Temp Monitoring • Cavity exhaust systems

Conveyor Specifications

• Microwave compatible specialized carriers and fixtures Edge Rail:.187”(.475cm) edge clearance1” (2.54cm) top and bottom clearance SMEMA compatibleSubstrate:Max. size 12” X 12”(30.5cm X 30.5cm) Min size 4” X 2” (10.2cm X 5.1cm)Board Stops:3 to 6 depending uponsubstrate/carrier size

Applications

• Industrial bonding/processing • Flip chip • COB (Chip On Board) • MCM assembly • Semiconductors • Fiber Optics Component Assembly • Structural Bonding • Smart Cards/RFID Tag

Lambda Technologies Inc. • 860 Aviation Parkway, Suite 900 • Morrisville, NC 27560Tel: (919) 462-1919

•

Fax: (919) 462-1929 • E-mail: lambda@microcure.com