KEW 5010/5020
8Pages

{{requestButtons}}

Catalog excerpts

KEW 5010/5020 - 1

Quality and reliability is our tradition LOGGER SERIES 3 channel Data Logger for multiple parameter recording Advanced KEW Logger Series mnfEnm Load/Leakage Current recording and Power Quality [Power Quality: Reference voltage, Swell, Dip, Short power Interruptions] The recorded data is downloadable onto a PC via USB Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor. LED flickers when the preset current / voltage value is [Available for Trigger / Capture Recording, Power Quality Analysis modes] Simplified Power Integration. [The "KEW LOG Soft 2" uses current and voltage recorded to calculate the integral power consumption] Various measurements are available with 4 recording modes: Normal, Trigger, Capture, Power Quality Analysis (only on KEW5020] 060,000 data points can be recorded when using 1 channel. Continuous measuring time: Approx. 10 days (Alkaline Battery] Lowpass Filter will filter out the in higher frequency har- > Supplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.

Open the catalog to page 1
KEW 5010/5020 - 2

hanneli input imulfaneous recording! of Leakage Current,, metal distribution board via the magnet on it's rear side 60,000 data points can be recorded when Ich is used, and when all the three channels are used, 20,000 data points per channel can be recorded. The logger can take external DC input via an AC/DC adaptor (Model 8320), ideal for long re- cording times. * Max recording time y life (approx 10-days with Alkaline battery) Use of optional AC Adopter is recommended for long time recording Normal recording mode Trigger recording mode Capture recording mode MODM '=or monitoring power...

Open the catalog to page 2
KEW 5010/5020 - 3

Power Quality Current, Voltage, Simplified Power The user friendly PC software System requirements PC with CPU: Pentium2 500MHz or higher and with operating Display: Resolution 800 x 600 dots, 65536 colors or more Hard-disk: space required 100Mbyte or more Others: with CD-ROM drive and USB drive * Windows® is a registered trademark of Microsoft in the United States * Pentium is registered trademark of Intel in the United States Via the software the following parameters can be set: time/date, recording intervals, the start of recording, recording methods, name of monitoring Selection of...

Open the catalog to page 3
KEW 5010/5020 - 4

^ ^ ^ Normal recording mode MADM '=or monitorin9 power line status or an intermit- NUKM tent leakage. Trigger recording mode TRIP '=or 0Dservin9 an irregular operation of an U ELCB/RCD, an irregular current / voltage. given interval (For moni- current / voltage against A choice of 15 recording intervals are available: 1 sec. to 60 min. Detects the value, time rent / voltage when the preset value is exceeded. When the detection level (i.e. preset value) is exceed- ed, 8 data points (True RMS values for approx. 0.8 sec) and peak value are recorded before and after the preset value is...

Open the catalog to page 4
KEW 5010/5020 - 5

The user friendly PC software "KEW LOG Soft 2" is supplied. System requirements with operating system of Windows8 Display: Resolution 800 x 600 dots, 65536 ^Normal and Trigger recording modes can be set up through A graph can be made by just one Hard-disk: space required 100Mbyte or more Others: with CD-ROM drive and USB drive * Windows® is a registered trademark of Microsoft in the Jnited States * Pentium is registered trademark of Intel in the United States Large data can be easily processed Display of Power Quality 5. The values of integral power con- sumption will be automatically input...

Open the catalog to page 5
KEW 5010/5020 - 6

Voltage Sensor Floating voltage can be measured "Floating voltage: phase to phase voltage not grounded Option : Small Clips adaptor Adaptor to convert the crocodile clips of the voltage sensor (8309) * Can be connected to the M5 size screw used at the terminals of standard RCD/ 3 voltage sensors are used. Measuring the floating voltage using 3 voltage sensors * Any clamp sensor (1 pc.) can be exchanged with the voltage sensor (1 pc). AC Adaptor (External Power Supply)

Open the catalog to page 6
KEW 5010/5020 - 7

Leakage current & Load current detection types

Open the catalog to page 7
KEW 5010/5020 - 8

Normal Recording Mode AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1 Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely §3fGty ^A^3fllil1QS I for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument. KYORITSU ELECTRICAL Factories:llwajima & Ehime http://www. kew-ltd.co.jp IThe contents of this leaflet are subject to change without notice

Open the catalog to page 8

All Kyoritsu catalogs and technical brochures

  1. KEW 5204BT

    2 Pages

  2. 2062BT

    2 Pages

  3. 3025A/3125A

    2 Pages

  4. 3121B/3122B

    2 Pages

  5. 3126

    2 Pages

  6. 3127

    2 Pages

  7. 3128

    4 Pages

  8. 3132A

    4 Pages

  9. 4106

    4 Pages

  10. 4200

    2 Pages

  11. 4202

    2 Pages

  12. 5202

    2 Pages

  13. 5410

    2 Pages

  14. 5510

    2 Pages

  15. 6010B

    2 Pages

  16. 6011A

    2 Pages

  17. 6016

    4 Pages

  18. 6305

    3 Pages

  19. 6315

    3 Pages

  20. 8035

    2 Pages

  21. KEW 2007R

    2 Pages

  22. 1030

    2 Pages

  23. 1021R

    2 Pages

  24. KEW 1019R

    2 Pages

  25. MODEL 1009

    1 Pages

  26. 2007A

    2 Pages

  27. KEW 2500

    2 Pages

Archived catalogs