company brochure
12Pages

{{requestButtons}}

Catalog excerpts

company brochure - 2

MULTI METERS Analogue Multimeters 1106 1109 1018H Hard case type Diode test Capacitance test Continuity buzzer Battery test Applicable standards Power source Dimensions LWD × × mm Weight Approx. DMM with AC/DC Clamp 2000/2001 2012R NEW Digital Multimeters KEW 1051/1052/1061/1062 AC/DC Clamp Sensor NEW KEW8115 Battery test Diode test Capacitance test Decibel hFE Auto power off Applicable standards Power source Dimensions LW × × D mm Weight Approx. ◦Permits extension of the AC and DC current ranges of almost any digital multimeters DMMswithout breaking the circuit under test. ◦Using KEW 8115...

Open the catalog to page 2
company brochure - 3

CLAMP METERS AC Digital Clamp Meters 2031 2007A 2017/2027 AC Analogue  Clamp Meters 2608A 2805 Continuity buzzer Frequency DUTY Diode test Frequency response Data hold Peak hold Auto zero Analogue output IEC 61010-1 CAT.Ⅲ 300V Applicable standards CAT.Ⅱ 600V IEC 61010-031 IEC 61010-2-032 Power source Battery life Dimensions LWD × × mm Weight Approx. AC/DC Digital Clamp Meters 2010 2033 2037 Fork Current Tester 2300R Continuity buzzer Diode test Capacitance test Frequency response Data hold Peak hold Auto zero 2056R:Auto sleep● Auto sleep ● Analogue output Applicable standards Power source...

Open the catalog to page 3
company brochure - 4

CLAMP METERS Leakage Clamp Meters stray magnetic field Frequency response Data hold Peak hold • (Auto sleep! Analogue output Water proof Applicable standards Power source Battery life Weight (Approx.) True RMS (Root Mean Square value) measurement Averaging Value When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave- form as the above displaysamples. However, when load current is affected by some distortions such as inverter, etc ., averaging value type clamp...

Open the catalog to page 4
company brochure - 5

EARTH TESTERS MODEL 4102A Conductor size True RMS Earth resistance Earth voltage Noize check Memory function Applicable standards IEC 61010-1 CAT.Ⅳ 300V Pollution degree 2 IEC 61010-031 IEC 61326 IEC 60529 IP40 Power source Dimensions LWD × × mm Weight Approx. Earth Resistance & Resistivity Tester KEW 4106 NEW Earth Resistance Measurements with 4, 3 and 2 Wires Earth ResistivityρMeasurement using WENNER method ●High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range ●Advanced filtering methodbased on FFT Fast Fourier Transformreduces noise interference for obtaining stable...

Open the catalog to page 5
company brochure - 6

Test voltage Measuring ranges Continuity test current ● 200mA 1mA rated insulation test current LIVE circuit warning Illuminated scale Lock-down test button for ● continuous operation Test lead ● resistance zero adjustment IEC 61010-1 CAT.Ⅲ 300V Applicable standards IEC 61557 IEC 60529 IP54 Power source Dimensions LWD × × mm Weight Approx, Test voltage Measuring ranges 1mA rated insulation test current Illuminated scale Test leads with remote control switch Applicable standards Power source Weight Approx.

Open the catalog to page 6
company brochure - 7

HIGH VOLTAGE INSULATION TESTERS MODEL 3121/3122/3123 3121 Test voltage Measuring ranges Automatic change Voltage measurement Polarization index measurement Lock-down test button for continuous operation Dimensions LWD × × mm Weight Approx. Applicable standards Power source Auto-discharge function Dual resistance scales Ni-Cd rechargeable battery 1.2V Test voltage up to 12kV, Resistance up to 35TΩ, Short-Circuit current up to 5mA. Graphic representation on large backlight display. ●Microprocessor controlled high voltage insulation resistance tester with diagnostic functions. ●Suitable for...

Open the catalog to page 7
company brochure - 8

LOOP/PSC TESTERS Single-pole phase test Phase rotation test 4116A Loop impedance ranges AC test current Three-phase 4-wire system 200〜690V phase-to-phase 100〜400V earth-to-phase AC 50/60Hz Automatic RCD lock circuit Display mains voltage before ● test Visual indication of correct wiring status Applicable standards IEC 61010-1 CAT.Ⅲ / Ⅳ 600V IEC 61243-3 CAT.Ⅱ 690V Pollution degree 2 IEC 60529 IP65 Power source Lock-down test button for continuous operation Operation voltage Applicable standards Continuity test DimensionsLWD × × mm 241.5×68.5×28.5 Weight Approx. Weight Approx. Rated tripping...

Open the catalog to page 8
company brochure - 9

PHASE INDICATORS With open phase checker MODEL 8030 Standard type Standard type CE type 8030 Operational voltage With fused test leads KEW 8031F 200〜480V AC 200V : within 60 minutes 480V : within 4 minutes Fuse Time limit for continuous Frequency response Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2CE Type IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2 CE Type Withstand voltage IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2 Weight Approx. Non-Contact Safety Phase Indicator KEW 8035 Safe testing without direct contact with live wires!!! ●New technology permits safe testing, without...

Open the catalog to page 9
company brochure - 10

LOGGERS Leak Logger MODEL 5000/5001 ●The leakage current value of 1 to 3 channels can be measured with the leakage clamp sensors, and 60,000 data can be stored ●Continuous measurement time   ◆Standard type About 25 days 5000◆Long life type About 40 days 5001 ●Direct data transmission to PC by USB connection ●The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software ●The leakage clamp sensor can be connected up to three channels ●4 recording modes are available for insulation...

Open the catalog to page 10
company brochure - 11

POWER METERS Compact Power Meter MODEL 6300 ●12 kinds of power measurements  ◆Voltage RMS ◆Current RMS ◆Active power ◆Apparent power ◆Reactive power  ◆Power factor ◆Active energy ◆Apparent energy ◆Reactive energy ◆Frequency  ◆Demand measurement ◆Current flowing on the neutral line Only on 3 phase 4 wire measurement ●4 types wiring system   ◆1 phase-2 wire 1ch ●Recording internal can be set between 1 second for 1 hour ●Demand function for Energy-Saving measurements ●Internal non-volatile memory for non-stop recording up to 10 days ●Accepts removable compact flash memory up to 1GB for...

Open the catalog to page 11
company brochure - 12

MULTI FUNCTION TESTERS /4\ fiafotv Warninna ■ Please read the ,Safetv Warnings' in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause **are*y a 9s ■ firei trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument. KYORITSU ELECTRICAL No.5-20,Nakane 2-chome, Meguro-ku, Tokyo, 152-0031 Japan Factory: Ehime, Japan IPRIMED WITHI In consideration of the environment, soy ink was used in this publication. ©The contents...

Open the catalog to page 12

All Kyoritsu catalogs and technical brochures

  1. KEW 5204BT

    2 Pages

  2. 2062BT

    2 Pages

  3. 3025A/3125A

    2 Pages

  4. 3121B/3122B

    2 Pages

  5. 3126

    2 Pages

  6. 3127

    2 Pages

  7. 3128

    4 Pages

  8. 3132A

    4 Pages

  9. 4106

    4 Pages

  10. 4200

    2 Pages

  11. 4202

    2 Pages

  12. 5202

    2 Pages

  13. 5410

    2 Pages

  14. 5510

    2 Pages

  15. 6010B

    2 Pages

  16. 6011A

    2 Pages

  17. 6016

    4 Pages

  18. 6305

    3 Pages

  19. 6315

    3 Pages

  20. 8035

    2 Pages

  21. KEW 2007R

    2 Pages

  22. 1030

    2 Pages

  23. 1021R

    2 Pages

  24. KEW 1019R

    2 Pages

  25. MODEL 1009

    1 Pages

  26. 2007A

    2 Pages

  27. KEW 2500

    2 Pages

Archived catalogs