General InformationOverviewTypeInputsOutputsAdditional functionsPageCODIX 529 –Display Hold, 12Two adjustable characteristic curve end points, MIN/MAX value detection0 ... 20 mA, 4 ... 20 mA0 ... 10 V, 2 ... 10 V CODIX 530 –Display Hold/Reset input, 13With integration functionTwo adjustable characteristic curve (totaliser)end points,Programmable mains humsuppression. 0 ... 20 mA, 4 ... 20 mA 0 ... 10 V, 2 ... 10 V CODIX 531 –Display Hold, 14For temp. measurementMIN/MAX value detection withwith resistance-data backup in case of PowerOff thermometerDisplay in °C or °F PT100, Ni100 CODIX 5 532 –Display Hold,16For temp. measurementinternal or external cold junction-with thermocouplescompensation, MIN/MAX value detection in case for PowerOff. Display in °C or °F J, K, N thermocouples CODIX 533 –0 ... 12 V andWhen a value is entered using the keys on36Setpoint generator/ 0 ... 24 mAthe front, this will appear on the outputTime-based of the device as either a current or a process adjustervoltage value. Manual operation or programmable time-based operation possible. U VSollwert 8 V3 V2 V10 s20 s30 s40 s50 sou. 4ou. 5PE. 4PE. 5 t s CODIX 550 Option:Display Hold,18serial interfaceserial interfaceprogrammable input characteristic curveRS232/422/485with 24 control points for voltage ormA ranges, MIN/MAX value detection. 0 ... 20 mA, 4 ... 20 mA0 ... 10 V, 2 ... 10 V + 10 VThermocouples B, E, J, KN, R, S, T0 ... 10 mV; + CODIX 5 551 Option:Display Hold,20For temperature serial interfaceprogrammable input characteristic curvemeasurement sensors RS232/422/485for mV/400/4000 Ω rangein the mV rangeMIN/MAX value detection 100 mVResistance thermometers PT100, PT1000, 0 ... 400/4000 Ω CODIX 552 Option: Display Hold 22With integration functionserial interfaceintegration function(totaliser)resetting (totaliser)RS232/422/485key programmable characteristic curve with 24 control pointsMIN/MAX value detection 0 ... 20 mA, 4 ... 20 mA0 ... 10 V, 2 ... 10 V + 10 V CODIX 5 553 Relays with -2 limit values,24With 2 limit values change-over contactlimit values resetting key,or optocouplerkey lock input,Option: serial inter-programmable characteristic curve face RS232/422/485with 24 control pointsMIN/MAX value detection, display hold 0 ... 20 mA, 4 ... 20 mA0 ... 10 V, 2 ... 10 V + 10 V CODIX 554 Relays with -2 limit values,26For temperaturechange-over contactlimit values resetting key,measurement sensorsor optocouplerkey lock input, in the mV rangeOption:programmable characteristic curveserial interfacewith 24 control pointsRS232/422/485MIN/MAX value detection, display hold Thermocouples B, E, J, KN, R, S, T 0 ... 10 mV; + 100 mVResistance thermometers PT100, PT1000, 0 ... 400/4000 Ω 2 www.kuebler.com 1/2008 |
|