Text version of the page
Power Supply
Measuring- and control inputs as well as auxiliary signals
■ Power supply
X1
X2
ramm
1 23456789 10 11
2
X1
1 2
DC version
AC version
1
10 ... 30 V DC
90 ... 260 V AC (N~)
2
GND4 (0 V DC)
90 ... 260 V AC (L~)
X3
Interface
9
9
GND3 (for Uout)
10
10
Uout +10 V/30 mA
11
11
Uout +24 V/50 mA only for power supply 90 ... 260 V AC
8
MP-Input Display-Hold
7
GND2 (MPI)
J I-X2
X2
1) Alternatively connect directly to DC supply (galvanic separation of control and measurement inputs)
Current input (I)
0 ... 20 mA / 4 ... 20 mA
GND1 (Analog)
2
Serial fiterfitce
- For data transmission and documentation
- Connection for programmable logic controllers
- Programming via PC
Voltage Measurement
Interface
RS232
RS485
RS422
1
GND
-
-
2
RxD
DO+/RI+
RI+
3
TxD
DO-/RI-
RI-
4
-
-
DO+
5
-
-
DO-
GND1 (Analogue)
2
Voltage input (U)
0 ... 10 V, 2 ... 10 V, -10 ... +10 V
3
Process ciisplay
Screw terminal, 2-pole, RM 5.08 Screw terminal, 11-pole, RM 3.81 Screw terminal, 5-pole, RM 3.81(*) Clamping bracket Gasket
Multilingual operating instructions 1 set of self-adhesive symbols * only with the interface option
6.550.012.X0X
Interface
0 = without interface
5 = RS232
6 = RS422
7 = RS485 -Supply voltage
0 = 90 .. 260 V AC 3 = 10 .. 30 V DC

pageCatalog pdf di En 2012-05-22-30