General Data and Instructions
(ÉCUbler
£6 Electromechanifristandard range
please refer to the technical data for the various counters
Frfntpanell
0 = no front bezel
1 = front bezel for panel with 2 screws
2 = front bezel with spring clip mount
Reset
0 = without reset
1 = manual push button reset
2 = remote reset
3 = large front bezel for panel with 2 screws 3 = remote- and manual reset
For further codes, please refer to the respective counters.
2.7 Versions with co|
Max. possible frequency depends on the type of coil used:
Coil type 05 =
0= 1= a0 =
a =
Max. frequency 8 Hz for DC 10 Hz for DC 25 Hz for DC 10 Hz for AC 18 Hz for AC
2.8 Special versions These are modifications of standard ver-
sions. The most common versions available are listed under the various type series.
In order to avoid queries, please state exact type designation, voltage and pulse frequency and other accessories if required, when ordering. If combinations and special versions are required, please send drawing with circuit diagram. In diffi-cult cases the availability can be clarified by a visit from our agent.
If a counter is only required to operate at a maximum of 10 cps, then one for 25 cps should not be used. This is primarily because of the higher service life of the 10 cps version compared to the 25 cps model. In addition the 10 cps counter has a higher duty cycle and a lower power consumption than the one for 25 cps.
The choice of spark quenching is also very important, particularly at high count speeds (refer to section 2.4 spark quenching). RC element, silicon diodes and some varistors can be obtained from us.
Certain counter types are supplied with a built in spark quenching. It should be ensured that the release contact on the preset counter will not be damaged by excessive breaking current or breaking voltage. If necessary, spark quenching should be provided here as well. The explanations given in the above para-graphs and the technical specifications of each counter should be noted carefully.
2.10 Approvafc
© c®«s
Many of our products are UL (Underwriters Laboratories Inc.) approved. CODIX 717 Multi-function counter in Ex proof version acc. to explosion-proof class EEX D llC T6.
RoHS
Kûbler is active worldwide and has made a company commitment to protecting the environment. Our product range is RoHS compliant.
7/2007

pageCatalog pdf di En 2012-05-22-30