40
Mass flowmeters The standard device with a very good price-to-performance ratioSuitable for the smallest amounts of flowThe high-end solution with a straight measuring pipe OPTIMASS 1010OPTIMASS 3010OPTIMASS 7010 Accuracy Liquid: ±0.2%; Gas: ±0.75%
Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5%
Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5%
Density: ±2kg/m >
3 3 3 (±0.5kg/m >
3 ) Communication ModbusModbusModbus Supply 12VDC12VDC12VDC Protection category IP67; NEMA 4XIP67; NEMA 4XIP67; NEMA 4X OPTIMASS 1300OPTIMASS 3300OPTIMASS 7300 Accuracy Liquid: ±0.2%; Gas: ±0.75%
Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5%
Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5%
Density: ±2kg/m >
3 3 3 (±0.5kg/m >
3 ) Input connections BinaryBinaryBinary Output connections mA, pulse, statusmA, pulse, statusmA, pulse, status Communication HART, FF, PA, DP, ModbusHART, FF, PA, DP, ModbusHART, FF, PA, DP, Modbus Supply 85…250VAC; 11…31VDC;20.5…26V AC/DC85…250VAC; 11…31VDC;20.5…26V AC/DC85…250VAC; 11…31VDC;20.5…26V AC/DC IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6
IP65; NEMA 4,4X
IP20; NEMA 1IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6
IP65; NEMA 4,4X
IP20; NEMA 1IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6
IP65; NEMA 4,4X
IP20; NEMA 1 Protection class: Compact (C) Field, isolated (F) Wall (W)
Rack (R) SensorOPTIMASS 1000OPTIMASS 3000OPTIMASS 7000Nominal diameter Device, EN 1092-1 DN 15…50DN1…4DN6…80 Connection EN 1092-1 DN 15…80DN 15DN10…100 Device, ASME B16.5 DN 1/2…2DN 1/25…4/25DN 1/4…3 Connection ASME B16.5 DN 1/2…3DN 1/2DN 1/2…4 Screw connection NPT -1/4“- Pressure stages EN 1092-1 PN 40,63,100PN 40,63PN 40,63,100 ASME B16.5 CL 150,300,600CL 150,300,600CL 150,300,600 Secondary pressu-re containment 100 bar30 bar100 bar Temperature range Process -40…130°C; -40…266°F-40…150°C; -40…300°F-40…150°C; -40…302°F Ambient (MFC 010) -40…65°C; -40…149°F-40…65°C; -40…149°F-40…65°C; -40…149°F Ambient (MFC 300) -40…60°C; -40…140°F-40…60°C; -40…140°F-40…60°C; -40…140°F Applied materials Sensor Stainless steelStainless steel, Hastelloy C22Stainless steel, Hastelloy C22, titanium Protection category Sensor IP 67; NEMA 4XIP 67; NEMA 4XIP 67; NEMA 4X Approvals Ex ATEX, FM, CSAATEX, FM, CSA, NEPSIATEX, FM, CSA, NEPSI Hygienic 3A, ASME Bioprocessing-EHEDG,3A,ASME Bioprocessing Custody transfer --PTB, NMI, NTEP Media Water xxx Liquids exc. water xxx Slurries x-x Gases xxx >