40 Mass flowmeters The standard device with a very good price-to-performance ratioSuitable for the smallest amounts of flowThe high-end solution with a straight measuring pipe OPTIMASS 1010OPTIMASS 3010OPTIMASS 7010 Accuracy Liquid: ±0.2%; Gas: ±0.75% Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5% Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5% Density: ±2kg/m
3 3 3 (±0.5kg/m
3 ) Communication ModbusModbusModbus Supply 12VDC12VDC12VDC Protection category IP67; NEMA 4XIP67; NEMA 4XIP67; NEMA 4X OPTIMASS 1300OPTIMASS 3300OPTIMASS 7300 Accuracy Liquid: ±0.2%; Gas: ±0.75% Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5% Density: ±2kg/m Liquid: ±0.1%; Gas: ±0.5% Density: ±2kg/m
3 3 3 (±0.5kg/m
3 ) Input connections BinaryBinaryBinary Output connections mA, pulse, statusmA, pulse, statusmA, pulse, status Communication HART, FF, PA, DP, ModbusHART, FF, PA, DP, ModbusHART, FF, PA, DP, Modbus Supply 85…250VAC; 11…31VDC;20.5…26V AC/DC85…250VAC; 11…31VDC;20.5…26V AC/DC85…250VAC; 11…31VDC;20.5…26V AC/DC IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6 IP65; NEMA 4,4X IP20; NEMA 1IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6 IP65; NEMA 4,4X IP20; NEMA 1IP66,67; NEMA 4,4X,6IP66,67; NEMA 4,4X,6 IP65; NEMA 4,4X IP20; NEMA 1 Protection class: Compact (C) Field, isolated (F) Wall (W) Rack (R) SensorOPTIMASS 1000OPTIMASS 3000OPTIMASS 7000Nominal diameter Device, EN 1092-1 DN 15…50DN1…4DN6…80 Connection EN 1092-1 DN 15…80DN 15DN10…100 Device, ASME B16.5 DN 1/2…2DN 1/25…4/25DN 1/4…3 Connection ASME B16.5 DN 1/2…3DN 1/2DN 1/2…4 Screw connection NPT -1/4“- Pressure stages EN 1092-1 PN 40,63,100PN 40,63PN 40,63,100 ASME B16.5 CL 150,300,600CL 150,300,600CL 150,300,600 Secondary pressu-re containment 100 bar30 bar100 bar Temperature range Process -40…130°C; -40…266°F-40…150°C; -40…300°F-40…150°C; -40…302°F Ambient (MFC 010) -40…65°C; -40…149°F-40…65°C; -40…149°F-40…65°C; -40…149°F Ambient (MFC 300) -40…60°C; -40…140°F-40…60°C; -40…140°F-40…60°C; -40…140°F Applied materials Sensor Stainless steelStainless steel, Hastelloy C22Stainless steel, Hastelloy C22, titanium Protection category Sensor IP 67; NEMA 4XIP 67; NEMA 4XIP 67; NEMA 4X Approvals Ex ATEX, FM, CSAATEX, FM, CSA, NEPSIATEX, FM, CSA, NEPSI Hygienic 3A, ASME Bioprocessing-EHEDG,3A,ASME Bioprocessing Custody transfer --PTB, NMI, NTEP Media Water xxx Liquids exc. water xxx Slurries x-x Gases xxx
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-57
pdf-page pdf di En 2008-10-42-14