34 Ultrasonic
flowmeters OPTISONIC 6300UFM 3030OPTISONIC 7060
TransducerUFC 300UFC 030UFC 060 Flexible clamp-on device with clamp-on mechanics suitable for industryUniversal 3-beam device for in-line measurement of liquidsUniversal 2-beam device for in-line measurement of process gases Accuracy ±1% of measured value±0.5% of measured value±1.0% of measured value Process conditions Input connections Liquids with max 5% proportion of solids and max 2% proportion of gasLiquids with max 5% proportion of solids and max 2% proportion of gasFor process gases BinaryBinary, mA (temp., pressure)- Output connections mA, pulse, statusmA, pulse, statusmA, pulse, status Communication HARTHART, PAHART Supply -IP66,67; NEMA 4,4X,6
IP65; NEMA 4,4XIP67; NEMA 6IP65; NEMA 4,4X
-IP66,67; NEMA 4,4X,6-
- 85…250 VAC; 11…31 VDC; 20,5…26 V AC/DC100 … 240VAC; 24VAC/DC12 … 28.8 VDC Protection class: Compact (C)
Field (F)
Wall (W) SensorOPTISONIC 6000UFS 3000OPTISONIC 7000Process connection EN 1092-1 DN 15…4000DN 25…3000; PN 10...100DN 50…600; PN 10,16,40 ASME B 16.5 DN 1/2 …160DN 1…120; CL 150 …1500DN 2 …24; CL 150…600 Temperature range Process -40…120°C; -40…248°F-25…220°C; -13…428°F-20…180°C; -4…356°F Ambient (incl.
transducer) -40…65°C; -40…149°F -40…65°C; -13…149°F-20…60°C; -4…140°F Applied materials Measuring pipe, flange Sensor in aluminiumSteel, stainless steel, HC4, DuplexSteel, stainless steel, HC4, Duplex Protection category Sensor IP67; NEMA 6IP 65,67,68; NEMA 4,4X,6,6PIP 66,67, NEMA 4,4X,6 Approvals Ex ATEXATEX, FM, CSA, NEPSIATEX, CSA Custody transfer -EN 1434- >