You may also be interested in
Cylinder, Relief valve, Helical screw flow-meter, Turbine flow-meter, High pressure pump
Text version of the page
Transfer Gear Pumps BT,BTH Power consumptionViscosity ν (mm2 /s)reg. power inputP (kW)Viscosity ν (mm 2 /s)reg. power inputP (kW)Viscosity ν (mm 2 /s)reg. power inputP (kW) Pump typeBT 0BT 1BT 2BT 3 BT 4BT 5BT 6 BT 7BTH 1/55BTH 1/105 BTH 2/100 BTH 2/130BTH 3/150Power input required at high viscosities Viscosities above values specified in the table require a higherpower input. In such cases the power input of the pump P1Pucan be determinedby means of the viscosity factor fν(see table page 10) as follows:P1Pu= PTab 76+ fν· QTabExample:BT4 n = 200 1/min; ν = 10000 mm2/s; p = 8bar with Ptab 76= 0.6 kW, table data at ν = 76 mm2/sfν= 27 x 10-3kW min/l QTab= 32 l/mingives power inputP1Pu= 1.46 kWKRACHTGmbH · Gewerbestr.20 · 58791 Werdohl, Germany · fon +49(0)2392/935-0 · fax +49(0)2392/935209 · mail info@kracht.eu · web www.kracht.eu 9 |
|