Gear Type Flow Meter

 Open the catalog to page 1

Gear Type Flow Meter VC

 Open the catalog to page 2

Gear Type Flow Meter VC KRACHT • The measuring gears are driven by the liquid flow on the principle of a gear motor. • The gears run without contact in the measuring chamber. The bearing elements are low-friction ball or plain bearings. • The movement of the gears is sampled without contact by means of two sensors located in the cover. Between sensor compartment and measuring chamber is located a pressure-resistant, non-magnetic separator plate. • When the measuring mechanism rotates by one tooth pitch, the sensor emits a signal which corresponds to the geometrical tooth volume Vgz. • The signal...

 Open the catalog to page 3

Gear Type Flow Meter VC KRACHT • Optimized for individual applications because the series have been rendered media-specific by means of differing clearances, bearing variants and materials. • Wide measuring ranges with sizes graduated to meet specific requirements. • Measurement independent of viscosity within the specified ranges. • Low pressure drop • High-response measurement • High working pressure • Low noise emission • High-precision measurement with outstanding reproducibility • Temperature-independent output signals over a wide temperature range • High degree of accuracy, even with low...

 Open the catalog to page 4

Gear Type Flow Meter VC KRACHT • The accuracy figures quoted by KRACHT refer to the geometric tooth volume Vgz, that is to say the percentage deviation applies to the current value in each case. • The linearity error over the entire measuring range is < ± 0.1 % • Reproducibility of a measured value is < 0.1 % • Accuracy checking forms part of quality inspection in every case. • On request the result of the test will be documented in the form of an accuracy characteristic curve; an example relating to a series 1 VC 1 is given below. • The accuracy values quoted by Kracht are confirmed by the DKD...

 Open the catalog to page 5

Gear Type Flow Meter VC KRACHT Design    gear motor Connection type    plate mounting/pipe connection Mounting position    optional Flow direction    optional Viscosity    1 ...1.000.000 mm2/s, (according to series) Max. pressure drop    A pmax = 16 bar Nominal    geom.    max. working pressure    Peak pressure    Sound pressure Resolution size toothvolume Standard- High pressure Standard- High pressure level version    version    version    version KRACHT GmbH • Gewerbestr. 20 • 58791 Werdohl, Germany • fon +49(0)23 92/935-0 • fax +49(0)23 92/935 209 • mail info@kracht.eu • web www.kracht.eu

 Open the catalog to page 6

Gear Type Flow Meter VC KRACHT * Measuring accuracy ± 3%; Linearity ±1.5% KRACHT GmbH • Gewerbestr. 20 • 58791 Werdohl, Germany • fon +49(4)23 921 / 5*35-0 • fax +49(0)23 92/955 209 •mail info@kracht.eu • web www.kracht.eu

 Open the catalog to page 7

Gear Type Flow Meter VC KRACHT Ordering example means: Nominal size 0.2 / Seal FKM / Series 1 / Plate mounting / Electronic standard Connection type P Plate mounting R Pipe connection Electronics S standard (-30 ... 120 °C) H high temperature (-30 ... 150 °C) K high temperature PLUS (-30 ... 220 °C) L low temperature version (-60 ... 200 °C) V without preamplifier (for plug-in display SD1) X intrinsically safe (ATEX) (switching amplifier has to be ordered separately) KX high temperature PLUS ATEX (-30 ... 200°C) (switching amplifier has to be ordered separately) Product name 55    1-8    version...

 Open the catalog to page 8

Gear Type Flow Meter VC Electrical Connection Standard version / High temperature version 24 Volt (brown) High temperature PLUS version Electrical connection (Round connector M 12 x 1/4-pin) (2) Channel 1 (white) Signal output channel 2 Signal output channel 2 Electrical Characteristics Number of measuring channels Working voltage Pulse amplitude Pulse shape with symm. output signal Signal output Pulse offset between two channels Power requirement Output power/channel UA ≥ 0.8 UB square wave pulse duty factor / channel 1 : 1 ± 15 % PNP (NPN on request) Signal Characteristics Channel A rising edge...

 Open the catalog to page 9

Gear Type Flow Meter VC Explosion-Proof Design (ATEX) Function • All volume counters are available in explosion-proof design according to ATEX. • The explosion-proof design consists of the volume counter • (intrinsically safe electrical apparatus) and the switching amplifier K 130 (associated electrical apparatus). The type of protection „intrinsic safety“ applies to this construction. • The volume counter is installed in the potentially explosive atmosphere. • The mounting of the amplifier K 130 is carried out in the safe area. • Volume counter and switching amplifier are electrically connected...

 Open the catalog to page 10

Gear Type Flow Meter VC

 Open the catalog to page 11

Gear Type Flow Meter VC

 Open the catalog to page 12

Gear Type Flow Meter VC KRACHT KRACHT GmbH • Gewerbestr. 20 • 58791 Werdohl, Germany • fon +49(0)2392/935-0 • fax +49(0)23 92/935 209 • mail info@kracht.eu • web www.kracht.eu

 Open the catalog to page 13

Gear Type Flow Meter VC Pressure Drop Series 4 / 5 Parameter: Viscosity (mm2/s)

 Open the catalog to page 14

Gear Type Flow Meter VC KRACHT Series 1, 2, 3, 4, 7 - Connection type P Nominal Available Weight Tightening size    series    torque

 Open the catalog to page 15

Gear Type Flow Meter VC KRACHT Series 1 - High pressure version (/79) Nominal size Tightening torque Nm Series 1 - Standard version Nominal Weight size kg m VC 12    53.5 Tightening    Dimensions torque Nm    mm KRACHT GmbH • Gewerbestr. 20 • 58791 Werdohl, Germany • fon +49(0)2392/935-0 • fax +49(0)23 92/935 209 • mail info@kracht.eu • web www.kracht.eu

 Open the catalog to page 16

Gear Type Flow Meter VC KRACHT Connection plate (Spheroidal cast iron) for VC3/79 and VC5/79 (high pressure) with side SAE flange connection Ordering    Weight    Dimensions code    kg    mm Connection plate for VC 12 and VC 16 with side SAE flange connection Ordering    Weight    Dimensions code    kg    mm mABCEF G    KLMN P    Rabe f KRACHT GmbH • Gewerbestr. 20 • 58791 Werdohl, Germany • fon +49(0)23 92/935-0 • fax +49(0)23 92/935 209 • mail info@kracht.eu • web www.kracht.eu

 Open the catalog to page 17

All KRACHT GmbH catalogs and technical brochures

  1. Brochure en

    16 Pages

    En
  2. Brochure en

    12 Pages

    En
  3. Brochure en

    16 Pages

    En
  4. Brochure en

    12 Pages

    En
  5. Brochure en

    12 Pages

    En
  6. Brochure en

    12 Pages

    En
  7. Brochure en

    20 Pages

    En
  8. Brochure en

    13 Pages

    En
  9. Brochure en

    32 Pages

    En
  10. Brochure en

    12 Pages

    En
  11. Brochure en

    20 Pages

    En
  12. Brochure en

    12 Pages

    En
  13. Brochure en

    13 Pages

    En
  14. Brochure en

    8 Pages

    En
  15. Brochure en

    24 Pages

    En
  16. Brochure en

    20 Pages

    En
  17. Gear Pumps KF 0

    16 Pages

    En
  18. Brochure en

    32 Pages

    En
  19. Brochure en

    17 Pages

    En
  20. Brochure en

    20 Pages

    En
  21. Product overview

    24 Pages

    En
  22. WL4.06 GB 05-05

    8 Pages

    En
  23. DuroTec® DT

    12 Pages

    En
  24. KF 730 ... 1500

    16 Pages

    En
  25. KF-F 2.5...112

    12 Pages

    En
  26. KP 0

    12 Pages

    En
  27. KF-F 2.5 ...112

    12 Pages

    En
  28. KF 2,5...630

    32 Pages

    En
  29. KP.../434

    16 Pages

    En
  30. KF 2.5... 200

    8 Pages

    En
  31. KP .../434

    16 Pages

    En