Dimensions (Units: mm)
Universal Measuring Probe Small Universal Measuring Probe
Body LCD Flicker Measuring Probe Small LCD Flicker Measuring Probe
Specifications
Item
CA-210 (Universal Measuring Probe) I CA-210 (Small Universal Measuring Probe) I CA-210 (LCD Flicker Measuring Probe) I CA-210 i■sin all LCD FWier Ucaiunno I'robe)
Receptor
Detector: Silicon photo cell
Measurement area
627 mm
610 mm
627 mm
610 mm
Acceptance angle
±2.5"
±5"
±2.5"
±5"
Pointing function
By LED
Measurement distance
30±10 mm
30±5mm
30±10 mm
30±5mm
Display range
Luminance
0.01 to 1000 cd/m2
0.01 to 3000 cd/m2
0.01 to 1000 cd/m2
0.01 to 3000 cd/m2
Chromaticity
Displayed in 4 or 3-digit value (Can be chosen)
Luminance
Measurement range
0.10 to 1000 cd/m2 10.30 to 3000 cd/m2 | 0.10 to 1000 cd/m2 | 0.30 to 3000 cd/m2
Accuracy
±2%±1 digit LCD (6500K, 9300K )*1
Repeatability^ a)
0.10 to 0.99 cd/m2 0.2%+1 digit 1.00 to 1000 cd/m2 0.1%+1 digit
0.30 to 2.99 cd/m2 0.2%+1 digit 3.00 to 3000 cd/m2 0.1%+1 digit
0.10 to 0.99 cd/m2 0.2%+1 digit 1.00 to 1000cd/m2 0.1%+1 digit
0.30 to 2.99 cd/m2 0.2%+1 digit 3.00 to 3000 cd/m2 0.1%+1 digit
Chromaticity
Measurement range
0.10 to 1000 cd/m2
0.30 to 3000 cd/m2
0.10 to 1000 cd/m2
0.30 to 3000 cd/m2
Accuracy
Calibration LCD (6500K, 9300K)
0.10 to 4.99 cd/m2 ±0.008 5.00 to 39.99 cd/m2 ±0.005 40.00 to 1000 cd/m2 ±0.003 160 cd/m2 ±0.002 (±0.004 for monochrome)
0.30 to 14.99 cd/m2 ±0.008 15.00 to 119.99 cd/m2 ±0.005 120.00 to 3000 cd/m2 ±0.003 160 cd/m2 ±0.002 (±0.004 for monochrome)
0.10 to 4.99 cd/m2 ±0.005
5.00 to 19.99 cd/m2 ±0.004
20.00 to 1000 cd/m2 ±0.003
160 cd/m2 ±0.002
(±0.004 for monochrome)
0.30 to 14.99 cd/m2 ±0.005
15.00 to 59.99cd/m2 ±0.004
60.00 to 3000 cd/m2 ±0.003 160 cd/m2 ±0.002 (±0.004 for monochrome)
Repeatability
LCD (6500K,9300K)
0.10 to 0.19 cd/m2 0.015(2 o) 0.20 to 0.49 cd/m2 0.008 (2 o) 0.50 to 1.99 cd/m2 0.003 (2 o) 2.00 to 1000 cd/m2 0.001 (2 o)
0.30 to 0.59 cd/m2 0.015(2 a) 0.60 to 1.49 cd/m2 0.008 (2 a) 1.50 to 5.99 cd/m2 0.003 (2 a) 6.00 to 3000 cd/m2 0.001 (2 a)
0.10 to 0.19 cd/m2 0.010(2 o) 0.20 to 0.49 cd/m2 0.005 (2 o) 0.50 to 0.99 cd/m2 0.002 (2 o) 1.00 to 1000 cd/m2 0.001 (2 o)
0.30 to 0.59 cd/m2 0.010(2 a) 0.60 to 1.49 cd/m2 0.005 (2 a) 1.50 to 2.99 cd/m2 0.002 (2 a) 3.00 to 3000 cd/m2 0.001 (2 a)
Flicker Contrast
method
Measurement range
5 cd/m2 or higher
15 cd/m2 or higher
Display range
0.0 to 100%
Accuracy
±1% (30 Hz AC/DC 10% sine wave) ±2% (60 Hz AC/DC 10% sine wave)
Repeatability
1% (2 o) (AC/DC 10% sine wave)
Flicker JEITA method *2
Measurement range
5 cd/m2 or higher
15 cd/m2 or higher
Accuracy
±0.5 dB (30 Hz AC/DC 10% sine wave)
Repeatability
0.3dB (2 o) (30 Hz AC/DC 10% sine wave)
Measurement
speed
(measurements/sec.)
xyLv*3
5 (4.5) 0.10 to 3.99 cd/m2 20(17) 4.00 cd/m2 or higher
5(4.5) 0.30 to 11.99 cd/m2 20(17) 12.00 cd/m2 or higher
5(4.5) 0.10 to 1.99 cd/m2 20(17) 2.00 cd/m2 or higher
5 (4.5) 0.30 to 5.99 cd/m2 20(17) 6.00 cd/m2 or higher
Flicker Contrast
16 measurements/sec. (16 measurements/sec.)
Flicker JEITA*2
0.5measurements/sec. (0.3 measurements/sec.) *4
Display
Digital
xyLv, XYZ, TAuvLv, u'v'Lv, RGB analyze
Chromaticity is displayed up to fourth decimal place. (Three-digit indication can be chosen.)
xyLv, XYZ, TAuvLv, u'v'Lv, RGB analyze
Chromati city i s di splayed up to fourth deci mal place. (Three-di gi t i ndi cati on can be chosen.) Flicker (Contrast method) *2
Analog
AxAyALv, R/G B/G AG, AR B/R G/R
AxAyALv, R/G B/G AG, AR B/R G/R, Flicker (Contrast method) *2
LCD
16 characters by 2 lines (with backlight)
SYNC mode
NTSC, PAL, EXT, UNIV, INT
Object under measurement
Vertical synchronizing frequency: 40 to 200 Hz I Vertical synchronizing frequency: 40 to 200 Hz (Flicker: 40 to 130 Hz)
Memory channel
100 channels
Analyzer function
Standard function
Interface
RS-232C (38,400 bps or below), USB (Rev.1.1)
Multi-point Measurement
Max. 5 points(Use 4-Probe Expansion Board CA-B14)
Software
SDK software (supplied as standard accessory)
Operating temperature/humidity range
0 to 40'C , relative humidity 85% or less(at 35-C)with no condensation
Storage temperature/humidity range
-20 to 55'C , relative humidity 85% or less(at 35-C)with no condensation
Input voltage range
100 - 240V~, 50-60 Hz, 50VA
Size
Main body: 340 (W) x 127 (H) x 216 (D)mm, Probe: 649 x 204 mm
Main body: 340 (W) x 127 (H) x 216 (D)mm, Probe: 649 x 232 mm
Main body: 340 (W) x 127 (H) x 216 (D)mm, Probe: 649 x 204mm
Main body: 340 (W) x 127 (H) x 216 (D)mm, Probe: 649 x 232mm
Weight
Main body: 3.58 kg, Probe: 520 g
Main body: 3.58 kg, Probe: 540 g
Main body: 3.58 kg, Probe: 520 g
Main body: 3.58 kg, Probe: 540 g
*1 : The chromaticity and luminance are measured under Minolta's condition (standard LCD is used). • Specifications are subject to change without notice.
*2 : Measurement of flicker (JEITA method) is supported by SDK software.
*3 : Measuring probe connected to probe connector P1 only,used USB (used RS-232C Baud rate: 38400 bps) *4 : Measured by Minolta's PC (P3-600 MHz)
The manufacturing center of Konica Minolta Sensing Inc. (Location: Aichi Pref., Japan) was approved by the British certification organization Lloyd's Register Quality Assurance for certification under the ISO 9001: 1994 international quality management system standards on March 3, 1995. Since its establishment in 1990, the center has carried out the
development and production of precision instruments and associated application software
for the measurement of color, light, and shape.
Certification was awarded to the center's quality management system, including design, manufacturer, management of manufacture, calibration and servicing.Certification was carried over to the ISO 9001: 2000 standards in February, 2003.
SAFETY PRECAUTIONS
JS0900L
CERTIFIED/
To ensure correct use of the instrument, please adhere to the following.
A•Before using the instrument, be sure to read the instruction manual. •Always use the specified power. Use of inappropriate power may result in afire or electric shock.
KONICA MINOLTA SENSING, INC.
Minolta Corporation / ISD Minolta Canada Inc. Minolta Europe GmbH Minolta France S.A.
Minolta UK Limited
Minolta Austria Ges.m.b.H. Minolta Camera Benelux B.V. Minolta Schweiz AG Minolta Italia s. r. l Minolta Svenska AB Minolta Hong Kong Limited
Shanghai Office Minolta Singapore (Pte) Ltd. KONICA MINOLTA SENSING, INC. Seoul Office
3-91, Daisennishimachi, Sakai.Osaka 590-8551, Japan
101 Williams Drive, Ramsey, New Jersey 07446, U.S.A. Phone: 1-888-ISD-COLOR (in USA), 201-529-6060 (outside) FAX: 201-529-6070 369 Britannia Road East Mississauga, Ontario L4Z 2H5, Canada Phone: 905-890-6600 FAX: 905-890-7199 Minoltaring 11, 30855 Langenhagen, Germany Phone: 0511-74040 FAX: 0511-741050
365-367, Route de Saint-Germain, 78424 Carrieres-Sur-Seine, France Phone: 01-30866161 FAX: 01-30866280 Precedent Drive, Rooksley Park, Milton Keynes, MK13 8HF, England Phone: 01-908200400 FAX: 01-908618662 Amalienstrasse 59-61,1131 Wien. Austria Phone: 01-87882-222 FAX: 01-87882-180 Postbus 6000 3600 HA Maarssen, The Netherlands Phone: 00(31)-30-2470860 FAX: 00(31)-30-2470861
Riedstrasse 6, 8953 Dietikon, Switzerland Phone: 01-7403727 FAX: 01-7422350
Via Stephenson 37, 20157, Milano, Italy Phone: 02-39011-1 FAX: 02-39011-219
Albygatan 114 P.O.Box 9058 S-17109 Solna, Sweden Phone: 08-627-7650 FAX: 08-627-7685
Room 208, 2/F, Eastern Centre 1065 King's Road, Quarry Bay, Hong Kong, China Phone: 2565-8181 FAX: 2565-5601
Rm. 1211, Ruijin Building No. 205 Maoming Road (S) Shanghai 20020, China Phone: 021-64720496 FAX: 021-64720214
10, Teban Gardens Crescent Singapore 608923 Phone: 6563-5533 FAX: 6561-9879
801, Chung-Jin Bldg., 475-22, BangBae-Dong, Seocho-ku, Seoul, Korea Phone: 02-523-972S FAX: 02-523-9729
9242-4885-15 ADKBPK© Printed in Japan
©2002, 2003 KONICA MINOLTA SENSING, INC.

pageCatalog pdf di En 2012-05-22-30