|
|
See other catalogues for KMB Systems
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Obvod mékkého rozbéhu pro transformätory | | | | | | | | | | TrafoSTART je elektronické relč urňené ke spinŕni jednofŕzovych transformŕtorů. Principem je kontrola magnetizace jŕdra transformŕtorů bčhem rozbéhu. V jednotlivych půlperiodŕch napŕjeciho napétf je jŕdro pfemagnetovŕno na opafinou polarětu s pfesnč definovanym prirůstkem magnetizace nastaveném podle typu transformŕtorů. Metoda Fězenf rozbéhu transformŕtorů zcela eliminuje zapfnacf proud transformŕtorů, pfěéemz je zajiSténa minimŕlni doba rozbéhu (od 0,06 s). Tento unikŕtnf princip je chrŕnén patentem CZ 296466. Magnetovacf impulsy jsou korěgovŕny podle průbéhu primŕrnfho napétf a tak je zajiStčna bezchybnŕ funkce s llbovolnou zŕtézl sekundŕrnfho vlnutf transformŕtorů TrafoSTART je vhodny prň transformŕtory vSech konstrukcf - El, Ul, C, toroidy a dalSi. K jednomu obvodu je mozno prěpojlt skuplnu paralelné spojenych transformŕtorů různych typů. TrafoSTART je urňen pfedevSfm prň Casto spinane transformŕtory a prň transformŕtory s vysokou pracovnf indukcf a nfzkymi ztrŕtaml. Obvod se snadno Instaluje do pffvodu primŕrnfho vintiti. Pfě zapojenf ovlŕdacfho vstupu TrafoSTARTu mule nahradlt stykafi transformŕtorů. Vestavénŕ funkce kontroly magnetizace béhem cele doby chodu transformŕtorů dovoluje bezproblémové provozovŕni transformŕtorů s vySSi pracovnf Indukcf, které jsou menai, lehcT a levnéjsT. | | | | | | | | | | Transformer Soft Starter/Switching The TrafoSTART Is an electronic relay for the switching single-phase transformers. The magnetization of the transformer core Is maintained In limits during energization. The transformer core Is remagnetlzed to opposite value of magnetization with exactly specified Increment In each half period of the supply voltage. The Increment of magnetization depends on type of transformer. The transformer starting method totally eliminates Inrush current with minimal start up time (from 0,06 s). This unique control procedure was patented. It has patent number CZ 296466. Magnetizing Impulses are revised according to the primary voltage waveform. This principle ensures error-free operation with any transformer secondary load. The TrafoSTART Is suitable for all kinds of transformers - El, Ul, C, toroidal, at al. Parallel connected transformers of different types can be connected to one TrafoSTART. The TrafoSTART Is recommended for frequently switched transformers and for low-losses transformers with high working Induction. The device Is easily installed into the primary lead. The TrafoSTART can replace transformer contactor, when control Input Is used. The embedded function of the supply voltage failure recognition allows to operate transformer with high working Induction without troubles. Solution with such transformer and the TrafoSTART Is then smaller In size, lighter and cheaper. | | | | | | | | | | %j Rozméry / Dimensions | | | | | | | | | | | | | | | | | StupeA krylf/ Degree of protection | IP20 | | | | Tfida ochrany / Protection class | II | | | | StupeA zneiiSteni prostfedi | | | | | / Cleanliness class | II | | | | RozmSry/Dimensions | 53x96x 60 mm | | | | Material krytu / Housing material | ABSsamozhäsivy/ABS | | | | Hmotnost/Weight | 200 g | | | | Montaz/Fixture | na 35 mm DIN Mihi podle DIN EN 50 022 | | | | | / 35 mm DIN rail according to DIN EN 50 022 | | | | Pripojenf/ Connections | vykonové svorky: prüfez vodice 0,2 - 4 mm2 | | | | | ovlädaci svorky: prüfez vodice 0,2 - 2,5 mm2 | | | | | / power terminals: conductor cross-section 0,2- 4mm2 | | | | | control terminals: conductor cross-section 0,2- 2,5 mm2 | | | | Pracovni teplota / Ambient temperature | 0°Caz 50°C/0°Cto50°C | | | | Skladovacl teplota / Storage temperature | -10°Cai70°C/-100Cto700C | | | | Max. vlhkost/ Max. humidity | 90 % nekondenzujlcl/90 % no condensation | | | | | | | | | | | | | 53(71) | | | | | | 58 | | | | | | | | | | | | | | 15 , 10 | | | | | | 5 | | | | | | | | | | \I3 | | | | | | | | | | | | | | KMB systems s.r.o., Tfida Dr. Milady Horŕkové 559,460 06 Llberec 7, Czech Republic, tel.: 485130 314, e-mail: kmb@kmb.cz, http://www.kmb.cz TU v Liberei - KEK FM, Hŕlkova 6,46117 Liberec, Czech Republic, tel.:485 353 626, e-mail: miroslav.novŕk@tul.cz, http://www.fm.tul.cz/~kel | | | | | | | | | | THIS PROJECT IS COFINANCED BY THE EUROPEAN REGIONAL DEVELOPMENT FUND AND MINISTRY OF INDUSTRY AND TRADE OF THE CZECH REPUBLIC TENTO PROJEKT JE SPOLUFINANCOVÄN EVROPSKYM FONDEM PRO REGIONÄLNI ROZVOJ A MINISTERSTVEM PRÜMYSLU A OBCHODU | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|