Digital multimeter - Klauke - #1

/ 21


catalogue search
Digital multimeter - Klauke
P. 01
Digital multimeter - Klauke
P. 02
Digital multimeter - Klauke
P. 03
Digital multimeter - Klauke
P. 04
Digital multimeter - Klauke
P. 05
Digital multimeter - Klauke
P. 06
Digital multimeter - Klauke
P. 07
Digital multimeter - Klauke
P. 08
Digital multimeter - Klauke
P. 09
Digital multimeter - Klauke
P. 10
Digital multimeter - Klauke
P. 11
Digital multimeter - Klauke
P. 12
Digital multimeter - Klauke
P. 13
Digital multimeter - Klauke
P. 14
Digital multimeter - Klauke
P. 15
Digital multimeter - Klauke
P. 16
Digital multimeter - Klauke
P. 17
Digital multimeter - Klauke
P. 18
Digital multimeter - Klauke
P. 19
Digital multimeter - Klauke
P. 20
Digital multimeter - Klauke
P. 21
Pages:
Digital multimeter - Klauke


See other catalogues for Klauke

Text version of the page
Digital multimeter
DM Series in detail
Part No. Catalogue No.
True effective value
DC A (A max.)
200 mA
200 mA
10
Maximum resolution (uA)
100
10
0,1
Greatestaccuracy (%)
1,0
1,0
1,2
AC A (A max.)
10
Maximum resolution (uA)
0,1
Greatestaccuracy (%)
1,5
DC V (V max.)
300
600
600
Maximum resolution (uV)
100
100
100
Greatestaccuracy (%)
1,5
0,54
0,5
AC A (A max.)
300
600
600
Maximum resolution (uV)
100 mV
100mV
100
Greatestaccuracy (%)
2,5
1,2
1,0
Resistance (MQ)
2
20
20
Maximum resolution (mfμ)
100
100
100
Greatestaccuracy (%)
2,5
0,8
0,8
10 0,1 0,8 10 0,1 1,0 1000 100 0,3 750 100 1,0 25 100 0,4
10 0,1 0,8 10 0,1 1,0 1000 100 0,3 750 100 1,0 25 100 0,4
10 0,01 0,2 10 0,1 1,0 1000 100 0,2 750 100
1,1 40 100
0,5
10 0,01 0,2 10 0,1 1,2 1000 100 0,2 750 100 1,3 40 100 0,5
Continuity and beeper Diode test Capacity
Frequency measurement Frequency threshold value (Hz) Temperature (T1) Temperature (twin conduit T1 ,T2) Display type
Display of updating rate (x/s) Capacity
Analogue bar chart Updating rate analogue (x/s) Optical RS-232 interface Automatic and manual range selection Automatic stop
Contactless voltage testing (EF) Data Hold (measured data memory) Minimum value / maximum value Relative compensation function Processing loopback Harmonics (HAR)
Safety category classification
CE
Limited lifetime warranty
• ••••••
• • •
45-400
40-400
40-400
50-500
50-500
40-500
40-500
• I •
Digital Digital
4 4
9999 9999
42Segmente 42Segmente
Digital
2,5 2000
Digital
2,5 2000
Digital
2,5 2000
Digital
3
2500
Digital
3
2500
20 Yes
20 Yes
Sleep
Yes
Yes
• •••••
only Max.
Yes
Yes
•• •
Ill, 300 V II, 600 V
III, 600 VII, 1000 V
III, 600 VII, 1000 V
III, 600 V II, 1000 V
III, 600 VII, 1000 V
II, 300 V
III, 300 V
*******
• I ••• I • I • I •