SPECIFICATIONS
LAS
X-
LAS
Path length range 0.25 to >4.5 km
(1 >
1 to >8 km
(1 >
Aperture diameter 0.152 m 0.328 mLens type Fresnel Fresnel
Optical wave length LED 880 nm 880 nm
Power output LED 80 mW (max.)
(1 >
80 mW (max.)
(1 >
Carrier frequency 7 kHz (0.5 duty cycle) 7 kHz (0.5 duty cycle)
Power requirements 12 VDC nominal (10.5 - 15) 12 VDC nominal (10.5 - 15)
Power consumption 0.5 A max. (path length dependant) 0.5 A max. (path length dependant) 3 A max. (window heater included) 1.7 A max. (window heater included)
Window heater self regulating at 55 ºC 14 W (non-regulating)
Onboard calibration test Yes Yes
Operating temperature range -20ºC to +50ºC -20ºC to +50ºC
Alignment Integrated pan and tilt adjustment. Removable pre-aligned sighting telescopes.
Signal strength meter.Physical dimensions 0.35 m length
(2 >
1.04 m length
(2 >
(including pan and tilt adjuster) 0.23 m width
(2 >
0.43 m width
(2 >
0.32 m height
(2 >
0.57 m height
(2 >
Weight 13.5 kg 30 kg
(1 >
Dependant of surface conditions and measurement height of LAS / X-LAS.
(2 >
Excluding sun cover for LAS and removable sighting telescopes.
SOLAR & ATMOSPHERIC SCIENCE
Kipp & Zonen B.V. reserve the right to alter specifications of the equipment described in this documentation without prior notice Kipp & Zonen B.V.
Delftechpark 36, 2628 XH DelftP.O. Box 507 2600 AM Delft
The Netherlands T +31 (0)15 2755 210 F +31 (0)15 2620 351 E info@kippzonen.com
www.kippzonen.com