Ø50 mm Ø150 mm Ø32 mm Ø110 mm Typical CMP series housing CMP3 housing
68 mm 68 mm

Specifications

Kipp & Zonen Data Sheet CMP Pyranometers - 9079 CMP 3 CMP 6 CMP 11 CMP 21 CMP 22

ISO CLASSIFICATIONResponse time (95%) Second Class18 s± 1%± 2.5%± 3%5 to 20 µV/W/m²20 to 200 First Class18 s± 1%± 1%± 1%5 to 20 µV/W/m²20 to 200 Secondary Standard± 0.5%± 0.2%± 0.2%7 to 14 µV/W/m²10 to 100 Secondary Standard5 s5 s± 0.5%± 0.2%± 0.2%7 to 14 µV/W/m²10 to 100 Zero offsets(a) thermal radiation (200 W/m²) (b) temperature change (5 K/hr)Directional error(at 80º with 1000 W/m² beam)Temperature dependenceof sensitivity Typical signal output foratmospheric applications Ω 0.1º -40 to +80ºC 310 to 2800 nm4000 W/m²± 2% Meteorologicalnetworks, PV panel and thermal collector testing, materials testing ± 7 W/m²± 2 W/m²± 10 W/m²± 1%(-10 to +40ºC) 0 to 15 mV Non-stability (change/year) Non-linearity (0 to 1000 W/m²) Tilt error (at 1000W/m²)

Other specifications

Sensitivity Impedance Level accuracy Ω Ω Ω Ω 1º -40 to +80ºC 310 to 2800 nm2000 W/m²± 10% Economical solutionfor routine measurements in weather stations, field testing ± 15 W/m²± 5 W/m²± 20 W/m²± 5%(-10 to +40ºC) 0 to 15 mV CMP instruments have a standard cable length of 10 m. Optional cable lengths 25 m and 50 mStandard 10k Thermistor or optional Pt-100 temperature sensor with CMP 21 and CMP 22 0.5º -40 to +80ºC 310 to 2800 nm2000 W/m²± 5% Good qualitymeasurements for hydrology networks, greenhouse climate control ± 15 W/m²± 4 W/m²± 20 W/m²± 4%(-10 to +40ºC) 0 to 15 mV 0.1º -40 to +80ºC 310 to 2800 nm4000 W/m²± 2% Meteorologicalnetworks, reference measurements in extreme climates, polar or arid ± 7 W/m²± 2 W/m²± 10 W/m²± 0.5%(-20 to +50ºC) 0 to 15 mV Secondary Standard5 s± 0.5%± 0.2%± 0.2%7 to 14 µV/W/m²10 to 100 0.1º -40 to +80ºC 200 to 3600 nm4000 W/m²± 1% Scientific researchrequiring the highest level of measurement accuracy and reliability ± 3 W/m²± 1 W/m²± 5 W/m²± 0.5%(-20 to +50ºC) 0 to 15 mV Operating temperature Spectral range (50% points) Maximum irradiance Expected daily uncertainty Recommended applications Individual directional response and temperature dependence test data with CMP 21 and CMP 22 Note: The performance specifications quoted are worst-case and/or maximum values

Go to www.kippzonen.com for your local distributor

HEAD OFFICE

+31 (0) 15 2755 210 F: +31 (0) 15 2620 351 Kipp & Zonen B.V. info@kippzonen.com Delftechpark 36, 2628 XH Delft P.O. Box 507, 2600 AM Delft The Netherlands T:

4414470-0806
Kipp & Zonen B.V. reserve the right to alter specifications of the equipment described in this documentation without prior notice

pageCatalog pdf di En 2012-02-07-16