Vanes ∅ : 14 mm, 70 mm and 100 mm Optical tacho. Hotwire Contact tacho. Contact temp. >
Class 300
Penetration temp. ∅ 100 mm, 70 mm vane probes. Detectionof flow direction and temperature included. Hygrometry Ambient temp.
Thermocouple K, J, T Pt100 >
Wireless probes Wireless connection.
CO/CO² Temp./Hygro./Air velocity >
Smart+ probes Automatically recognized by theinstrument when connected. Supplied with calibration or adjusting certificate. Modules :
• Differential pressure and1 Thermocouple input.• 4 Thermocouple inputs.• Current/voltage• Climatic conditions >
Interchangeable modules PC interface (wireless)
AMI300
User-friendly multifunction Evolutive and accurate Large colored manufacturer of graphic display Wireless and SMART + probes Storage up to 12,000 measurement points Protective cover with probe notch
Smart+ Wire >
Multifunction
Datalogger
• Data logging, recording datasets and intervention planning.
Rf module >
Functions Parameters Probe types Measurement range
Manometer Pressure/Air Velocity/Airflow/Temperature ModulesPitot tubes
Debimo blades • -500 to +500 Pa, -2500 to +2500 Pa, -10,000 to +10,000 Pa,
-500 to +500 mBar, -2000 to +2000 mBar.
• 3 to 100 m/s and 0 to 99,999 m³/h. • K : -200 to +1300°C, J : -100 to +750°C, T : -200 to +400°C. >
Thermocouple K, J, T • -50 to +250°C and -100 to +400°C.• K : -200 to +1300°C, J : -100 to +750°C, T : -200 to +400°C.
Professional thermometer Temperature Pt100 : Ambient, contact, penetration Thermocouple K, J, T , ... 4 module inputs • 3 to 98 %RH and -20 to +80°C.• 3 to 98 %RH and -40 to +180°C.• -20 to +80°C. Thermo-hygrometer Temperature/Humidity Hygro-temp. probeHygro-high temp.
Pt100 Vane thermo-anemometer Air velocity/AirflowTemperature Vane probePt100 • ∅ 14 mm : 0,8 to 40 m/s, ∅ 70 mm : 0.3 to 35 m/s and ∅ 100 mm : 0.2 to 35 m/s. • -20 to +80°C.
• 0 to 99,999 m³/h. • 0,15 to 30 m/s.• -20 to +80°C.
• 0 to 99,999 m³/h. Hotwire thermo-anemometer Air velocity/AirflowTemperature Hotwire, telescopic and gooseneck-shaped hotwire Pt100 Tachometer Tachometry Optical/ Contact • 60 to 60,000 rpm and 30 to 30,000 rpm. Climatic conditions Temperature/Hygrometry/Air Pressure Module • -20 to +80°C, 3 to 98 %RH and 800 to 1, 100 mbar. Multifunction Air velocityTemperature/Hygrometry Probe • 0,15 to 30 m/s, 5 to 95 %RH and -20 to 80°C. Current/voltage 2 module inputs • 0 to 2,5 V, 0 to 10 V, 0 to 4-20 mA. Air quality CO² or CO/temperature/Hygrometry 3 probes : CO, CO²,CO²-Hygro-Temperature • 0 to 1,000 ppm and -20 to +80°C.• 0 to 5,000 ppm, -20 to +80°C and 3 to 95 %RH. >
5