Carrier-frequency pulse amplifiers
19
Versions
• Round stainless steel housing for all
measuring cells
• Aluminium die-cast housing for gear flow meters
• Cartridge housing for micro meters and gear
flow meters
• Double pickup for forward / backward
detection and pulse multiplication
Carrier frequency pickups detect contactless the rpm of
the KEM flow meters. Each time a gear tooth passes by, a
free running oscillator is damped.
The frequency of the resulting amplitude modulation of
the carrier is equal to the wheel `s rpm and therefore
corresponds to the value of the flow. The output signal of
the pickup is amplified, converted and transmitted in the
form of current or voltage rectangular pulses.
Carrier frequency pickups are characterized by a wide
frequency range, low power consumption and high noise
immunity.
For applications in hazardous areas, we offer intrinsically
safe sensors and amplifiers with Ex protection in accordance
with ATEX, RTN, CSA and other testing standards.
More information is available at:
www.kem-kueppers.com
Technical Data
• Frequency range: 0.5 – 5,000 Hz
• Frequency output: Push-Pull or Open
Collector
• Medium temperature: up to +150°C
• Ex-approval
Compact carrier-frequency impulse pickup system with integrated
amplifier in a screw-on stainless steel housing. Suitable for almost
all KEM flow meters
Plug-in compact carrier-frequency impulse pickup system with an
integrated amplifier for gear meters in cartridge design
Plug-in carrier-frequency impulse pickup system with double pickup
for gear flow meters with rotation direction recognition and frequency
doubling
VTE*/P
VTE-C
TD
|
|