Specifications. Excitation I = 1 mA
Series 3 L ... 10 L Standard Pressure Ranges (FS) in bar
PR
-1
-0,5 -0,2
-0,1
0,1
0,2
0,5
1
2
5
10
20
PD
0,1
0,2
0,5
1
2
5
10
20
50
PAA
0,1
0,2
0,5
1
2
5
10
20
PA
1
2
5
10
20
50
100
200
400
600
Signal Output typ.* [mV]
75
50 25
15
15
30
60
100
140
200
225
225
225
225
225
225
225
Overpressure
-1
-1 -1
-1
2,5
2,5
2,5
3
4
7
15
30
100
200
300
600
900
PD, neg. Overpressure [-]
1
1
1
2
3
5
7
10
10
PD- 9 L, max. Line Pressure
50
PD-10 L, max. Line Pressure
200 « 1)
1000 225 1100
PR: Vented Gauge. Zero at atmospheric pressure PAA: Absolute. Zero at vacuum PA: Sealed Gauge. Zero at atmospheric pressure (at calibration day) PD: Differential * ± 40%
Bridge Resistance @ 25 °C Constant Supply Insulation @ 500 VCC
a
mA Ma
3500
1 nominal
100
± 20%
5 mA (see Remarks)
--------------------------------------------------------------------84
PR-10 L-0.5 (1) SN EQ925 (2)
-----------------------------------------------------------------59/05
(3) Temp
4) Zero (5) +270
(6) Comp
(7) dZero
[°C]
[mV] [mV]
[mV]
[mV]
-8.6
-5.5 -50.6
-60.8
-2.6
1.0
-2.6 -49.1
-59.7
-1.4
25.8
4.6 -46.6
-58.2
0.0
50.6
11.3 -45.6
-58.6
-0.3
80.7
19.0 -46.4
-61.3
-3.0
COMP R1
= 220kOhm (8)
R4 = 56.0 Ohm (8)
ZERO
-2.2 mV (9)
P_atm
962 mbar (10
SENS
112.5 mV/bar at 1.000 mA
SENS
450 mV/bar at 4.000 mA (11)
(14) Lnorm
(15) Lbfsl
(12) [bar]
(13) [mV]
[%FS]
[%FS]
0.000
0.0
0.00
0.06
0.250
112.2
-0.07
-0.06
0.500
224.9
0.08
0.06
Operating Temperature Compensated Range (1) Storage Temperature Vibration (20...5000 Hz) Endurance (FS @ 25 °C)
°C °C °C
g
Cycles
-30...100
0...50 (3 L...5 L)
-40...100 20
>100 x 106 FS
-55...150 (optional, 0 >15 mm) -10...80 (6 L...10 L) -60...150 (optional)
Housing and Diaphragm Seal Ring Oil Filling
Dead Volume Change @ 25 °C
Electrical Connection Wires (pd-9 l, pd-10 l, 10 l)
Stainless steel, type 316 L
3 L...5 L: Nitrile 6 L..10 L: Viton®
Silicone oil (1)
<0,1mm3 / FS
0,09 mm2, 12 x 0 0,1 mm, silicone sheathed, 0 1,2 mm,
length 7 cm (10 l), 10 cm (pd-9 l, pd-10 l)
Long Term Stability Ok (16) Lot 649 (17) Test 500 Volt ok (18) Supply 1.000 mA (19)
31.01.06 (20) GOLI.D03DqK (20)
(the values indicate the max. error @ 1 mA supply)
Compensated Range 0...50 °C
Compensated Range -10...80 °C
TC (Zero) (4) [mV/°C]
Stability [mV]
TC (Zero) [mV/°C]
Stability [mV]
Series 3 L / 4 L
0,0375
0,75
-
-
Series 5 L
0,025
0,50
-
-
Series 6 L / 7 L / 8 L
0,025
0,50
0,050
0,75
Series 9 L
0,0175
0,50
0,0375
0,75
Series 10 L
0,0125
0,25
0,025
0,50
Each sensor is delivered with a calibration sheet with the following data:
1. Type (PR-10) and range (0,5 bar) of pressure sensor
2. Serial number of pressure sensor (not standard)
3. Test temperatures
4. Uncompensated zero offset in mV
5. Zero offset values, in mV, with test resistance (270 k£l) (for factory computation only)
6. Zero offset, in mV, with calculated compensation resistor R1 or R2
7. Temp. zero error, in mV, with compensation resistor R1 or R2
8. Compensation resistor values R1 / R2 and R3 / R4
9. Offset with compensation resistors R1/ R2 and R3 / R4 fitted (fine adjustment of zero with R5 potentiometer)
10. Ambient pressure, zero reference for absolute sensors < 20 bar
11. Sensitivity of pressure sensor
12. Pressure test points
13. Signal at pressure test points
14. Linearity (best straight line through zero)
15. Linearity (best straight line)
16. Results of long term stability
17. Lot-type (on request, identification of silicon chip)
18. Voltage insulation test
19. Excitation (constant current)
20. Date of test--------Test equipment
Remarks:
- The indicated specifications only apply for constant current supply; the sensor should not be excited higher than 1,5 mA. If supply is > 1,5 mA, signal shifts can occur due to self-heating. The sensor signal is proportional to the current. When exciting with constant voltage, the zero offset values remain the same, the sensitivity decreases approx. 1% per +5°C.
- If exposed to extreme temperatures, the compensation resistors should have a temperature coefficient of < 50 ppm/°C. Sensor and resistors can be exposed to different temperatures.
- The sensors may be ordered with integrated compensation resi­stors (surcharge).
Accuracy (2) Offset at 25 °C Temperature Error Sensitivity
Line Pressure Influence Natural Frequency (Resonance)
%FS 0,25 typ. (1) 0,5 max.
mV < 20 mV (compensated with R5 of 22 a (3))
% / °C < 0,01 (0...50 °c) < 0,02 (-10...80 °c)
mV/bar < 0,0125 (PD-9 L, PD-10 L)
kHz > 30
(1)
(2)
Others on request.
Including linearity, hysteresis and repeatability. Linearity calculated as best straight line through zero.
Note: Generally, accuracy and overload is improved by factor of 2 to 4 if the sensor is used in the range of 0...50 %FS
External compensation, potentiometer not supplied.
Temperature-Coefficients of Zero
Options
- Diaphragm/Housing: Hastelloy C-276
- Oil for low temperatures. Fluorinated oil. Olive oil
- Integrated temperature sensor (version PA, PAA, PR)
- Special characteristics: Linearity, overpressure, lower TC-zero
- Special tests
- Compensation PCB fitted
- Mathematical modelling: See data sheet Series 30 X
Subject to alterations
02/2009
KELLER AG für Druckmesstechnik St. Gallerstrasse 119 CH-8404 Winterthur Tel. +41 (0)52 - 235 25 25 Fax +41 (0)52 - 235 25 00
KELLER Ges. für Druckmesstechnik mbH Schwarzwaldstrasse 17 D-79798 Jestetten Tel. +49 (0)7745 - 9214 - 0 Fax +49 (0)7745 - 9214 - 60
Companies approved to ISO 9001
www.keller-druck.com

pageCatalog pdf di En 2012-02-07-17