| | Specifications. Excitation I = 1 mA Series 3 L ... 10 L Standard Pressure Ranges (FS) in bar | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | PD, neg. Overpressure [-] | | | | | | | | | | | | | | | | | | | | PD- 9 L, max. Line Pressure | | | | | | | | | | | | | | | | | | | | PD-10 L, max. Line Pressure | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | PR: Vented Gauge. Zero at atmospheric pressure PAA: Absolute. Zero at vacuum PA: Sealed Gauge. Zero at atmospheric pressure (at calibration day) PD: Differential * ± 40% | |
| | | |
| | Bridge Resistance @ 25 °C Constant Supply Insulation @ 500 VCC | | | | --------------------------------------------------------------------84 PR-10 L-0.5 (1) SN EQ925 (2) -----------------------------------------------------------------59/05 | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 450 mV/bar at 4.000 mA (11) | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | Operating Temperature Compensated Range (1) Storage Temperature Vibration (20...5000 Hz) Endurance (FS @ 25 °C) | | -30...100 0...50 (3 L...5 L) -40...100 20 >100 x 106 FS | -55...150 (optional, 0 >15 mm) -10...80 (6 L...10 L) -60...150 (optional) | |
| | Housing and Diaphragm Seal Ring Oil Filling Dead Volume Change @ 25 °C Electrical Connection Wires (pd-9 l, pd-10 l, 10 l) | Stainless steel, type 316 L 3 L...5 L: Nitrile 6 L..10 L: Viton® Silicone oil (1) <0,1mm3 / FS 0,09 mm2, 12 x 0 0,1 mm, silicone sheathed, 0 1,2 mm, length 7 cm (10 l), 10 cm (pd-9 l, pd-10 l) | |
| | Long Term Stability Ok (16) Lot 649 (17) Test 500 Volt ok (18) Supply 1.000 mA (19) 31.01.06 (20) GOLI.D03DqK (20) | |
| | | |
| | | | | | | | | | | | (the values indicate the max. error @ 1 mA supply) | Compensated Range 0...50 °C | Compensated Range -10...80 °C | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Each sensor is delivered with a calibration sheet with the following data: 1. Type (PR-10) and range (0,5 bar) of pressure sensor 2. Serial number of pressure sensor (not standard) 3. Test temperatures 4. Uncompensated zero offset in mV 5. Zero offset values, in mV, with test resistance (270 k£l) (for factory computation only) 6. Zero offset, in mV, with calculated compensation resistor R1 or R2 7. Temp. zero error, in mV, with compensation resistor R1 or R2 8. Compensation resistor values R1 / R2 and R3 / R4 9. Offset with compensation resistors R1/ R2 and R3 / R4 fitted (fine adjustment of zero with R5 potentiometer) 10. Ambient pressure, zero reference for absolute sensors < 20 bar 11. Sensitivity of pressure sensor 12. Pressure test points 13. Signal at pressure test points 14. Linearity (best straight line through zero) 15. Linearity (best straight line) 16. Results of long term stability 17. Lot-type (on request, identification of silicon chip) 18. Voltage insulation test 19. Excitation (constant current) 20. Date of test--------Test equipment Remarks: - The indicated specifications only apply for constant current supply; the sensor should not be excited higher than 1,5 mA. If supply is > 1,5 mA, signal shifts can occur due to self-heating. The sensor signal is proportional to the current. When exciting with constant voltage, the zero offset values remain the same, the sensitivity decreases approx. 1% per +5°C. - If exposed to extreme temperatures, the compensation resistors should have a temperature coefficient of < 50 ppm/°C. Sensor and resistors can be exposed to different temperatures. - The sensors may be ordered with integrated compensation resistors (surcharge). | |
| | Accuracy (2) Offset at 25 °C Temperature Error Sensitivity Line Pressure Influence Natural Frequency (Resonance) | %FS 0,25 typ. (1) 0,5 max. mV < 20 mV (compensated with R5 of 22 a (3)) % / °C < 0,01 (0...50 °c) < 0,02 (-10...80 °c) mV/bar < 0,0125 (PD-9 L, PD-10 L) kHz > 30 | |
| | | Others on request. Including linearity, hysteresis and repeatability. Linearity calculated as best straight line through zero. Note: Generally, accuracy and overload is improved by factor of 2 to 4 if the sensor is used in the range of 0...50 %FS External compensation, potentiometer not supplied. Temperature-Coefficients of Zero | |
| | | |
| | Options - Diaphragm/Housing: Hastelloy C-276 - Oil for low temperatures. Fluorinated oil. Olive oil - Integrated temperature sensor (version PA, PAA, PR) - Special characteristics: Linearity, overpressure, lower TC-zero - Special tests - Compensation PCB fitted - Mathematical modelling: See data sheet Series 30 X | |
| | | |
| | | | |
| | | |
| | KELLER AG für Druckmesstechnik St. Gallerstrasse 119 CH-8404 Winterthur Tel. +41 (0)52 - 235 25 25 Fax +41 (0)52 - 235 25 00 KELLER Ges. für Druckmesstechnik mbH Schwarzwaldstrasse 17 D-79798 Jestetten Tel. +49 (0)7745 - 9214 - 0 Fax +49 (0)7745 - 9214 - 60 | |
| | | |
| | Companies approved to ISO 9001 | | |
| | | |
| | | | | | | | | | |