Sealed Gauge or Absolute

INTRINSICALLY SAFE INTELLIGENT MANOMETER - 13762 KELLER

SPECIFICATIONSM

Range
ANO

G

AUGE

/ M

ANO

R

ECORD Vented Gauge or Absolute
In M ANO G AUGE and M ANO R ECORD the measuring ranges aredivided by 12 bit or 3000 points.The resolution is determined by the measuring range and thenumber of measuring points. All instruments can be supplied with 8 bit, 10 bit or 12 bitresolution. Range Resolution Resolution 1000 mbar0,3 mbar-1…2 bar1 mbar 10 bar3 mbar 30 bar10 mbar 100 bar0,03 bar300 bar0,1 bar 600 bar0,2 bar 1000 bar0,3 bar • Specific Characteristics • Environmental Characteristics Total Accuracy
(1) Operating Temperature°C- 10…60 Compensated Range Range 0…50°C±0,1% typ.±0,2% max.Measuring Intervalsec1 (programmable)
(2) °C0…50Storage Temperature°C- 30…80 Display
(2) °C0…50
(1) Includes linearity, repeatability, hysteresis, temperature and resolution of the display (2) others upon request • Electrical Characteristics • Mechanical Characteristics See data sheet of transducer See data sheet of transducer Supply2 Lithium-Batteries 3 V (included) Battery-Life> 200 days at continuous operationOutput Signal:NumericalRS 232 (M Manometer HousingFaradex Transducer Total Weightapprox. 250 g Pressure Connection ProtectionIP 65 • Guidelines
ANO R
ECORD ) The certificate for these instruments is registered at the LCIE in France under the following number: LCIE 01 ATEX 6001 X. These instruments meet the basic requirements which are established in the guidelines of the European Community: - Directive EMC 89/336/EEC - Directive ATEX 94/9/CE • Options (on request)- External Transducer (max. 10 m cable) / - Special Programs / - Logger Software and K101 Cable • Special conditions for safe use in hazardous applications The Intelligent Manometer is an “intrinsically safe apparatus”; it can be mounted in explosive atmospheres. When the apparatus is mounted in dangerous area, equipment must not be connected to the terminal block. When the apparatus is mounted in non dangerous area, the terminal block can be only connected to a certified intrinsically safe equipment which the electrical parameters do not exceed the following values: U 6,5 V I 100 mA Operating ambient temperature: T5: -10 °C to +80 °C T6: -10 °C to +65 °C
LOGGER The Logger-Software allows the read-out of the stored datafrom the M ANO R ECORD .The data transfer takes place viathe serial interface on the PC and must not be done inintrinsic area! The M ANO R ECORD is connected through a cable K101(supplied with Logger software). The LOGGER-software offers many further processingpossibilities of the read-out data, and meets all the require- ments of modern Windows-Software: - Graphical Display- Tabulated Display- Export into other Windows-Programs - Storage into Files Subject to alterations KELLER AG für Druckmesstechnik St. Gallerstrasse 119CH-8404 WinterthurTel. 052 - 235 25 25Fax 052 - 235 25 00 KELLER Gesellschaft für Druckmesstechnik mbH Schwarzwaldstrasse 17D-79798 JestettenTel. 07745 - 9214 - 0Fax 07745 - 9214 - 50 Companies approved to ISO 9001 / EN 290013/02 www.keller-druck.com