Digital Indicator for pressure transmitters
• Universal Application, all Signal-Inputs
• Dimensions 48x96 mm
• Serial Interface RS485/RS422
• CE-marked (Tested to EN50081-1 and EN50082-2)
Universal digital indicator for pressure transmitters. Offers the possibility to process all stan­dard signal-inputs. The RS-485-/422 interface connects the instrument to a PC for data acquisition. Four different models cover all configurations (outputs, switching contacts etc.).
EV-101...104
Specifications:
Display Range Signal-Inputs
-1999...9999 resp.
4...20 mA, 0...20 mA 0...±10V 0...±100mV
-19'999...99'999 Ri = 5Ohm Ri = 1 MOhm Ri = 10MOhm
Supply
Operating-/Storage Temperature
Accuracy
Housing
Panel Cut-Out
Protection
Integrated Transmitter Supply Integrated Bridge Supply Integrated Bridge Supply
Different thermocouples as well as PT100, PT130, NÌ100
90...265Vac, 50 or 60 Hz, approx. 10VA 10...50°C/-10...70°C ± (0,05% + 3 digit) 48mmx96mmx173mm (HxWxD) 44mmx92mm (HxW) IP65 front side
24 V, electrically isolated (all models) 10V, electrically isolated (EV-101/EV-102) 0...12V, electrically isolated (EV-103/EV-104) Programmable in 0,01-V-steps, max. 30 mA Accuracy 0,05 V, ripple <5mA 2 x change over contacts, max. 1A/250Vac or 5A/30Vdc 0.10V, 0.20V, 4.20 mA
Electrically isolated (500Vdc/peak ac) Response: 32 ms for 63%, 100 ms for 99% Max. burden 900Ohm, max. current 22 mA Accuracy 0,2%; resolution 0,05% Temperature influence < 100ppm/K Programmable damping filter RS485/422, electrically isolated max. 9600 baud; 2- or 4-wire
SELECTION CHART
Function EV-
101 102 103 104
Display Digits
4 4 5 5
4 Software Alarms
vvvv
2 Alarm Relays
vv
2 Function Buttons
vvvv
2 Status Inputs
vv
User Linearisation
vvvv
Maths Functions
vvvv
10 V Transducer Supply
vv
0...12V Transd. Supply
vv
24V Transmitter Supply
vvvv
RS485/RS422
vv
Analogue Output, programmable VV
Alarm Relay Output (EV-102/EV-104)
Analogue Output (EV-103/EV-104)
Serial Interface (EV-103/104)
Maths Functions:
- Square root, 3/2- and 5/2-root
- Maximum, minimum, averaging value
- Tara, automatic Zero adjustment
Linearisation:
- Input of up to 24 calibration points, suitable for i.e. tank contents measurements.
Order Description
EV-100, EV-102, EV-103, EV-104