Data Sheet Mano Gauge / Record / Cali - KELLER - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for KELLER

Text version of the page
Sealed Gauge or Absolute Range

Data Sheet Mano Gauge / Record / Cali - 13762 KELLER

SPECIFICATIONSM

ANO

G

AUGE

/ M

ANO

R

ECORD

M

ANO

C

ALI Vented Gauge or Absolute Sealed or Vented Gauge
In M ANO G AUGE and M ANO R ECORD themeasuring ranges are divided by 12 bit or 3000 points. In M Range Resolution Resolution Range Resolution 30 mbar0,01 mbar300 mbar0,1 mbar 1000 mbar0,3 mbar -1…2 bar1 mbar 10 bar3 mbar 30 bar10 mbar 100 bar0,03 bar300 bar0,1 bar 600 bar0,2 bar 1000 bar0,3 bar -1…2 bar0,5 mbar-1…10 bar1,8 mbar -1…25 bar4,3 mbar 200 bar0,03 bar 350 bar0,05 bar 700 bar0,1 bar
ANO C ALI over 13bit or 6000 points.The resolution is determined by themeasuring range and the number of measuring points. • Specific Characteristics • Environmental Characteristics Total Accuracy
(1)M ANO G AUGE / R ECORD M ANO C ALI Operating Temperature°C- 10…60 Compensated Range Range 0…50°C±0,1% typ.0,05 % typ.±0,2% max.0,1% max.Measuring Interval
(5) °C0…50Storage Temperature°C- 30…80 Display
(2) sec0,5
(adjustable) 0,5
(5) °C0…50
(1) Includes linearity, repeatability, hysteresis, temperature and resolution of the display (5) others upon request (2) x 2 for two transducers (not for M ANO C ALI ) • Electrical Characteristics • Mechanical Characteristics See data sheet of transducer See data sheet of transducer SupplyLithium-Battery 3,6 V (included) Battery-Life> 200 days at continuous operation Manometer HousingPolyamid 12 Transducer Total Weightapprox. 250 g Pressure Connection ProtectionIP 65
(4) Output Signal (optional)- Analog
(3)(M ANO R ECORD / G AUGE ) 4..20 mA or 0..10 V- Numerical
(M ANO R ECORD / C ALI ) RS 232
(3) The use of an analog signal requires an external supply between 10…28 VDC (4) > 100 days for M ANO C ALI • Options (on request)-Manometer Housing in Metal* - 1 or 2 external Transducers (remote)* -Transmitter Output Connector* - Special Programs -Logger Software and K101 Cable -Intrinsically Safe Version (EEx-ia)**
only M ANO R ECORD and M ANO G AUGE LOGGER The Logger-Software allows the read-out of the storeddata from the Intelligent Manometer.The data transfer takes place via the serial interface on the PC. The M
ANO R
ECORD /M
ANO C
ALI is connected through acable K101 (supplied with Logger software). The LOGGER-software offers many further processing possibilities of the read-out data, and meets all the requirements of modern Windows-Software: - Graphical Display - Tabulated Display - Export into other Windows-Programs - Storage into Files
Subject to alterations KELLER AG für Druckmesstechnik St. Gallerstrasse 119CH-8404 WinterthurTel. 052 - 235 25 25Fax 052 - 235 25 00 KELLER Gesellschaft für Druckmesstechnik mbH Schwarzwaldstrasse 17D-79798 JestettenTel. 07745 - 9214 - 0Fax 07745 - 9214 - 50 Companies approved to ISO 9001 / EN 290012/00 www.keller-druck.com

pageCatalog pdf di En 2012-05-22-30