video corpo

Measurement Techniques for Characterizing Graphene, Carbon Nanotubes, and Nano-Materials and Devices
1Pages

{{requestButtons}}

Catalog excerpts

Measurement Techniques for Characterizing Graphene, Carbon Nanotubes, and Nano-Materials and Devices - 1

MEASUREMENT TECHNIQUES FOR CHARACTERIZING GRAPHENE, CARBON NANOTUBES, AND NANO-MATERIALS AND DEVICES LOW POWER, LOW VOLTAGE, LOW RESISTANCE Measurement Technique for Hall Voltage and Resistivity Measurements Nanovoltmeter Vxy = Transversal Voltage, Hall Voltage with applied B Technique for Measuring Resistance as a Function of Gate Voltage Circuit to Measure Drain Family of Curves on a Carbon Nanotube Ground Unit or SMU3 (if required) Quantum Hall Effect Measurements on Graphene Current vs. Voltage Characteristics of Carbon Nanotube FET Resistance vs. Gate Voltage of Graphene Device Longitudinal Resistance of a Graphene Layer on a Silicon Substrate as a Function of Substrate Voltage 25000 23000 Vsubstrate (volts) Avoiding Sources of Error When Measuring Low Power Materials and Devices Noise: External Noise Sources • Low Frequency Noise • Johnson Noise Use the Delta Mode Method to Eliminate Voltage Offsets and Noise The Delta method consists of alternating the current source • External Noise Sources = interferences created by motors, computer screens, or other electrical equipment polarity and using a moving average of voltage readings to calculate the resistance. Averaging reduces the noise bandwidth and therefore Test Lead Resistance: Eliminate Lead Resistance by Using the 4-Wire Method • Control these External Noise Sources by: δV = linearly changing thermoelectric voltages ––Shielding and filtering. ––Remove or turn-off the noise source. ––When using DC instruments, integrate each measurement for an integer number of power line cycles. The line cycle noise will “average out” when the integration time is equal to an integration number of power line cycles. Measured Resistance: V M/I = RSample + 2RLead Measured Resistance: VM/I = R Sample Eliminate Thermoelectric Voltage Effects Voltmeter Copper Test Leads Metal A Copper Test Leads Metal A • Construct test circuits using the same materials for interconnects. Use the Current Reversal Method to Eliminate Voltage Offsets (VEMF ) Ways to Reduce Thermoelectric Voltages Measurement with Positive Polarity • Minimize temperature gradients within the test circuit. Measurement with Negative Polarity • Allow the test equipment to warm up. Current Source Temperature Gradient Thermoelectric voltages are generated when dissimilar metals (Metal A and Metal B) in the circuit are at different temperatures (T1 and T2). • Use an offset compensation method. Voltage Measurement: Use Instrumentation with Sufficient Sensitivity Use Appropriate Current Source Use a Nanovoltmeter to Measure Voltage Drops • Current source should be bipolar to perform current reversals to eliminate voltage offsets and reduce noise. • When measuring the resistances of conductors or other low power materials, very small voltages are measured, typically in the microvolt and nanovolt range. • Current source should be capable of accurately sourcing very low currents (<1E-6A) for low level test devices and materials. • To measure these very small voltage drops, use a sensitive voltmeter such as a nanovoltmeter. • Verify the product specifications to make sure the measurement resolution and accuracy are sufficient to perform the sensitive measurement part of your application. • The current source should have an adjustable voltage compliance to limit voltage to a safe level to avoid damage to the device. • The current source should have constant output so user knows the exact value forced to the material – unlike using a voltage source and a resistor. © Copyright 2011 Keithley Instruments, Inc. A Greater Measure of Confidence

Open the catalog to page 1

All Keithley Instruments catalogs and technical brochures

  1. 6220-6221

    5 Pages

  2. 6482

    3 Pages

  3. 2520

    8 Pages

  4. 2606B

    13 Pages

  5. 2601B

    20 Pages

  6. AFG1000 Series

    13 Pages

  7. 6 Series B MSO

    69 Pages

  8. 3 Series MDO

    36 Pages

  9. 4 Series MSO

    40 Pages

  10. RTPA2A

    6 Pages

  11. 4200-SCS

    16 Pages

Archived catalogs